Viessmann Vitodens 242-F Installation And Service Instructions Manual page 72

Gas/solar condensing storage combi boiler
Table of Contents

Advertisement

Code 1
"Heating circuit ..."
Coding in the delivered condition
Extended economy function adjusted outside temperature
A6:36
Extended economy mode not ac-
tive
Extended economy function mixer
A7:0
Only for heating circuit with mixer:
Without mixer economy function
Pump idle time, transition reduced mode
A9:7
With pump idle time: Heating cir-
cuit pump "OFF" if set value is
modified by changing the operating
mode or changing the set room
temperature
Weather-compensated/room temperature hook-up
b0:0
Only for heating circuit with mixer
and remote control:
Heating mode/reduced mode:
Weather-compensated
Economy function room temperature
b5:0
Only for heating circuit with mixer
and remote control:
Without room temperature-de-
pendent heating circuit pump logic
function
Parameter address
With heating circuit pump logic function:
b5:...
Heating circuit pump "OFF"
1
RT
2
RT
3
RT
4
RT
72
(cont.)
RT
+ 5 K
>
actual
set
RT
+ 4 K
>
actual
set
RT
+ 3 K
>
actual
set
RT
+ 2 K
>
actual
set
Possible change
A6:5
Extended economy mode enabled;
to
i.e. at a variably adjustable value be-
A6:35
tween 5 and 35 °C, plus 1 °C, the
burner and heating circuit pump stop
and the mixer closes. The basis for
this is the adjusted outside tempera-
ture. The adjusted outside tempera-
ture is based on the actual outside
temperature and a time constant,
which takes into account the cooling
down of an average building.
A7:1
With mixer economy function (exten-
ded heating circuit pump logic):
Heating circuit pump also "OFF":
If the mixer has been trying to
close for longer than 20 min.
Heating circuit pump "ON":
If the mixer changes to control
function
If there is a risk of frost
A9:0
Without pump idle time
A9:1
With pump idle time, adjustable from
to
1 to 15.
A9:15
1 = short idle time
15 = long idle time
b0:1
Heating mode: Weather-compensa-
ted
Reduced mode: With room tempera-
ture hook-up
b0:2
Heating mode: With room tempera-
ture hook-up
Reduced mode: Weather-compen-
sated
b0:3
Heating mode/reduced mode: With
room temperature hook-up
b5:1
Heating circuit pump logic function,
to
see the following table.
b5:8
Heating circuit pump "ON"
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
+ 4 K
+ 3 K
+ 2 K
+ 1 K

Advertisement

Table of Contents