Display Shows: "SUN" "7:00 – 7:00"
Press the (UP) button until the desired
hour appears on the screen and press the
(Accept) button to confirm selection.
Display Shows: "SUN" "7:00 – 7:00"
"Set OFF Minute".
Press the (UP) button until the desired
minute appears on the screen and press
the (Accept) button to confirm selection
and advance to the next day.
Display Shows: "MON" "7:30 – 15:30"
Note: Continue with same procedure for
Monday through to Saturday.
E) Filter Life
Select the Appropriate Filter Mode
i. Remaining Life
ii. Filter Reset
iii. Filter Life
i)
To Select Remaining Life mode
(Prog>Filter Life>Accept>Remaining Life)
Display Shows: "Remaining Life"
Press the (Cancel) or (Accept) button to
revert back to the main menu.
ii)
To Select the Filter Reset mode
(Prog> Filter Life >Accept>filter
reset>Accept)
Display Shows: "Filter Reset"
Press the (Accept) button to confirm
selection at which time you are prompted
"Are you sure?". Press (Accept) once
more reset the filter and to return to the
Filter Life Menu.
iii)
To Select the Filter Life mode
(Prog> Filter Life >Accept>Set Filter
Life>Accept)
Display Shows: "Set Filter Life"
Pressing the (UP) button increases the
5000 litres value in increments of 500
litres to a maximum value of 12000 litres.
Press the (Accept) button to confirm
selection and the display reverts to the
Filter menu.
F) To Service Menu
"Set OFF hour".
"Set ON hour".
"XXXX litres"
"5000 Litres".
Select Appropriate Service Mode
i.
Error Codes
ii.
Boiling Temp
iii.
Chiller Temp
iv.
Calib Reset
v.
Software Version
vi.
Temp Show ON/OFF
i)
Product Error Codes
(Prog>Service>Accept>Error Codes)
This function allows easy identification of
problems occurring with the unit by
service technicians.
ii)
For Boiling Unit Display Temp mode
(Prog>Service>Accept>Boiling Temp)
Display Shows: "XXX ˚C"
This function displays the current hot
water temperature.
Press the (Cancel) button to revert back
to the main menu.
iii)
For Chiller Unit Display Temp Mode
(NOT USED ON LAZER PRODUCTS)
(Prog>Service>Accept>Chiller Temp)
Display Shows: "XXX ˚C"
Press the (Cancel) button to revert back
to the main menu.
iv)
For Calibration Reset mode
(Prog>Service>Accept>Calib.Reset>Accep
t)
Display Shows: "Calib. Reset"
This function recalibrates the boiling
water unit to boiling point. Press the
(Accept) button to recalibrate the boiling
point. Press (Accept) again at the "Are
You Sure" prompt. Press the (Cancel)
button to revert back to the Main menu.
v) To Display the Software Version
(Prog>Service>Accept>Software
Version>Accept)
vi)
Temp Show On/Off
(Prog>Service>Accept>TempShow
ON/OFF)
This function allows the temperature of
the water within the boiling water unit to
be displayed permanently on the screen.
Press the (Accept) button to confirm
selection and the display reverts to the
main menu.
9.