FOR SERVICE TECHNICIAN'S USE ONLY
Display Codes
Likely Failure Condition
F5
E0
Door and switches do not agree
(Clean mode - on some models)
Oven Control/
MRC
P7-5
Y
P7-4
Y
F6
E1
Over temp cook
E2
Over temp clean
E3
Over temp (warming drawer)
Suggested Corrective Action Procedure
1.
Press CANCEL>CANCEL>START to enter the Diagnostics Mode and verify the error
code.
2.
Press the CANCEL/OFF key. Press CANCEL>CANCEL>START to re-enter the
Diagnostics Mode. With "TEST ON" displayed, open the oven door and fully engage the
door switch. If the display does not change from "UI" to "UO," go to Step 4. If the display
Door Position Switch
does change, go to Step 3.
Y
3.
Inspect door and frame for warping or misalignment keeping the door from fully engaging
the door switch. Make any necessary repairs then go to Step 7.
4.
Unplug range or disconnect power.
5.
Verify the actuating rod connection from the front frame to the door switch.
6.
If there is damage to wires or connectors, replace the harness. If there is no damage to
wires or connectors, replace the door switch.
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
9.
Press CANCEL/OFF key. Select and start the SELF-CLEAN or PRECISE CLEAN function.
Observe for at least 1 minute to ensure that operation is normal.
10. Go to the Diagnostics Mode and scroll to the Faults display to clear faults.
1.
Press CANCEL>CANCEL>START to enter the Diagnostics Mode and verify the error
code.
2.
Unplug range or disconnect power.
3.
Replace control.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power.
6.
Verify operation is normal.