Table 1: Low temperature correction factors for open-circuit voltage
Lowest Expected Ambient Temperature (°C/°F)
24 to 20 / 76 to 68
19 to 15 / 67 to 59
14 to 10 / 58 to 50
9 to 5 / 49 to 41
4 to 0 / 40 to 32
-1 to -5 / 31 to 23
-6 to -10 / 22 to 14
-11 to -15 / 13 to 5
-16 to -20 / 4 to -4
-21 to -25 / -5 to -13
-26 to -30 / -14 to -22
-31 to -35 / -23 to -31
-36 to -40 / -32 to -40
Alternatively, a more accurate correction factor for the
open-circuit voltage can be calculated using the following
formula:
��
= �� − ��
Voc
T is the lowest expected ambient temperature at the
system installation site.
α
is the voltage temperature coefficient of the selected
Voc
module (refer to corresponding datasheet).
Electrical calculations and design must be performed by a
competent engineer or consultant.
Please contact Canadian Solar's technical support team
for additional information pertaining to engineering
optimization and approval of project specific module
string lengths.

4.0 UNPACKING AND STORAGE

PRECAUTIONS
 Modules should be stored in a dry and ventilated
environment to avoid direct sunlight and moisture. If
modules are stored in an uncontrolled environment,
the storage time should be less than 3 months and
extra precautions should be taken to prevent
connectors from being exposed to moisture or sunlight,
like using connector endcaps.
EN-Rev IM/GN-RM-EU/1.21P Copyright © June, 2021. CSI Solar Co., Ltd.
× (���� − ��)
������
Correction Factor
1.02
1.04
1.06
1.08
1.10
1.12
1.14
1.16
1.18
1.20
1.21
1.23
1.25
 Unpack module pallets carefully, following the steps
shown on the pallet. Unpack, transport and store the
modules with care.
 Modules must always be unpacked and installed by two
people. Always use both hands when handling modules.
Do not
lift modules by their wires or junction box, lift
them by the frame.
 Stacks of modules should contain no more than 12
modules, and the frames should be aligned.
Do not
place excessive loads on the module or twist the
module frame.
Do not
stand, step, walk and/or jump on modules
under any circumstances. Localized heavy loads may
cause severe micro-cracks at cell level, which in turn
may compromise module reliability and void Canadian
Solar's warranty.