Mounting Methods With Single-Axis Tracker - Canadian Solar CS5AH-180M Installation Manual Of Replacement

Solar modules
Table of Contents

Advertisement

6.4 MOUNTING METHODS WITH SINGLE-AXIS TRACKER

 The bolts and clamps used in this section should follow
the requirements in 6.1 and 6.2.
 Under any conditions the junction box should not
become in contact with the subjacent racking structure.
For any single axis tracker installation method with
portrait one row, bearing house cannot be allowed to
locate in junction box position.
 If any racking structures, especially bearing house,
have to be located under the modules, the gap H
between the frame and the racking structure should be
Tracker 1P Clamping method
Overlap width between clamp and frame:
Frame top side ≥ 10mm
Frame bottom side ≥ 15mm
The allowable maximum twist angle of the module is 0.5
degree.
EN-Rev IM/GN-RM-EU/1.21P Copyright © June, 2021. CSI Solar Co., Ltd.
at least 25mm.
 If your tracker design cannot meet the above distance
requirement, please contact Canadian Solar technical
support department in writing for advices.
B Value
Module type
(mm)
CS6XH-P
300
CS6X-P-PLUS
 Please contact the tracker manufacturer and Canadian
Solar's technical support department for details in
regard to specific projects
Clamp length C
Test load
(mm)
≥40
+2400/-2400
www.csisolar.com
(Pa)

Hide quick links: