Lennox MERIT Series Installation Instructions Manual page 23

Downflow air discharge
Table of Contents

Advertisement

Maximum Allowable Exhaust Vent Pipe Length (in ft.)
Winter Design Temperatures Single - Stage High Efficiency Furnace
Winter Design
Temperatures
°F (°C)
1
32 to 21
(0 to -6)
20 to 1
(-7 to -17)
0 to -20
(-18 to -29)
1
Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
2
Poly-Propylene vent pipe (PP) by Duravent and Centrotherm.
NOTE - Concentric terminations are the equivalent of 5' and should be considered when measuring pipe length.
NOTE - Maximum uninsulated vent lengths listed may include the termination(vent pipe exterior to the structure) and cannot exceed 5 linear feet or the maximum allowable
intake or exhaust vent length listed in table 7 or 8 which ever is less.
NOTE - If insulation is required in an unconditioned space, it must be located on the pipe closest to the furnace. See Figure 28.
3
Vent length in the table is equivalent length. Each elbow is equivalent to 5ft of straight pipe and should be included when measuring total length.
TABLE 9
Vent Pipe
Diameter
045
PVC
1-1/2 in
20
2 in
18
2-1/2 in
13
3 in
9
1-1/2in.
15
2 in
9
2-1/2 in
5
3 in
1
1-1/2 in
10
2 in
5
2-1/2 in
1
3 in
N/A
Conditioned
Space
3
Without Insulation In Unconditioned Space For
Unit Input Size
070
PP
PP
PVC
2
2
N/A
20
N/A
16
31
28
N/A
24
N/A
9
18
18
N/A
20
N/A
8
18
16
N/A
13
N/A
1
8
8
N/A
15
N/A
3
12
10
N/A
7
N/A
N/A
2
2
Conditioned
Space
Pipe Insulation
Unconditioned
Space
Figure 28
Page 23
090
PP
PVC
PVC
2
N/A
N/A
N/A
50
48
30
42
N/A
36
35
35
29
N/A
N/A
N/A
32
29
27
24
N/A
20
19
19
14
N/A
N/A
N/A
22
19
18
15
N/A
12
10
10
7
Exhaust
Pipe
Intake
Pipe
110
PP
2
N/A
30
N/A
29
N/A
24
N/A
14
N/A
15
N/A
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents