POTS Troubleshooting
When the POTS LED is red, the port is in a fault condition. To correct the problem, perform
the following:
• Contact the OLT administrator and ensure the port is provisioned and working. If the port
• Disconnect the CPE wiring and wait 30 seconds. If the Red LED turns off, the trouble is a
ODN Interface Troubleshooting
The successful use of the ODN interface connection relies on several factors being within
tolerance. The components must:
• Be clean and dry (refer to Cleaning and Inspection of Components below).
• Have mechanically tight connections.
• Contain the proper optical signal levels. Refer to "Signal Level Verification" on page 45.
6418771XGX-5B
Check reflective
No
power with PON
power meter
Yes
Is power
present?
No
Check for
defective optical
connection
is provisioned and working, proceed to the next step.
short in the housing wiring. If the RED LED remains on, the unit is probably bad.
Network LED off
Is there
Yes
a failure at
the OLT?
Replace ONT
No
Yes
Is connection
defective?
Figure 24. Network LED Flowchart
Work with
OLT admin
to resolve
Network LED solid green
Repair/Clean
connection
Troubleshooting