SC847 JBOD Chassis Manual Contents Chapter 1 Introduction ................1-1 Overview ......................1-1 Shipping List ....................1-1 Components ....................1-2 Drives ......................1-2 Power Supply ....................1-2 Cooling ......................1-2 Control Board ....................1-2 Mounting Rails ....................1-2 Where to get Replacement Components ............1-2 Returning Merchandise for Service..............
Page 5
Contents Power Fail ....................... 3-3 Overheating ..................... 3-3 Drive Carrier LEDs ..................3-4 Power Supply LEDs ..................3-4 Chapter 4 Chassis Setup and Maintenance ........... 4-1 Overview ......................4-1 Power Up/Power Down Sequences ..............4-2 Power Up ......................4-2 First Use or Power Cord Plug-In ..............4-2 After Normal Shutdown by BMC or Power Button ........
Page 6
BMC ........................ 6-8 BMC ADMIN User Password ................6-8 IP Address ....................... 6-8 Appendix A SC847 JBOD Power Supply Specifications ...... A-1 Appendix B Compliance ................B-1 Appendix C BPN-SAS3-846EL Backplane Specifications ....C-1 Appendix D BPN-SAS3-847EL Backplane Specifications ....D-1...
(Titanium Level) The following safety models associated with the SC847 JBOD have been certified as compliant with UL or CSA: 847JBOD-12. Shipping List Refer to the Supermicro website for the latest shipping lists and part numbers for your chassis model.
SC847 JBOD Chassis Manual Components The SC847 JBOD 4U high-performance chassis includes the following features: Drives The chassis supports forty-four hot-swap 3.5" SAS or SATA hard disk drives, 24 in the front and 20 in the rear. The drives are supported by two backplanes.
For faster service, RMA authorizations may be requested online (http://www. supermicro.com/support/rma/). Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping.
Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
Page 12
SC847 JBOD Chassis Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Page 13
Chapter 2: Warning Statements for AC Systems !تحذٌز جسذٌة اصابة ًتتسبب ف حالة ٌوكي أى ًاًك ف خطز ًٌٌع هذا الزهز الذوائز بالوخاطز الٌاجوة عي ي على علن ، ك هعذات تعول على أي قبل أى الكهزبائٍة حىادث أي وقىع وٌع...
SC847 JBOD Chassis Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Chapter 2: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
SC847 JBOD Chassis Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Page 17
Chapter 2: Warning Statements for AC Systems auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen. ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
SC847 JBOD Chassis Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
Chapter 2: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
SC847 JBOD Chassis Manual א א ז ז ו ו ר ר ע ע ם ם ג ג י י ש ש ה ה מ מ ו ו ג ג ב ב ל ל ת ת ! ! א א ז ז ה ה ר ר ה ה...
Page 21
Chapter 2: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
SC847 JBOD Chassis Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
Chapter 2: Warning Statements for AC Systems امداد الطاقة بوحدات عدة اتصاالت جهاز ال يكون لهذا قد الكهرباء عن وحدة ال لعسل كافة االتصاالت يجب إزالة 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
SC847 JBOD Chassis Manual מ מ ת ת ח ח ב ב פ פ נ נ ל ל ה ה א א ח ח ו ו ר ר י י !הרה אז קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך...
Chapter 2: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ת ת י י א א ו ו ם ם ח ח ו ו ק ק י י ה ה ח ח ש ש מ מ ל ל ה ה א א ר ר צ צ י י !אזהרה...
SC847 JBOD Chassis Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
Page 27
Chapter 2: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター 製品を設置する場合、 提供または指定された接続ケーブル、 電源コードとACアダプター...
Page 29
Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
Chapter 3: System Interface Chapter 3 System Interface Overview The server includes a control panel on the front that houses power buttons and status monitoring lights. The externally accessible hard drives display status lights. The power supply displays status lights visible from the back of the chassis. Figure 3-1.
SC847 JBOD Chassis Manual Control Panel Buttons The chassis includes two push-buttons that control power to the system. Power The main power switch applies or removes primary power from the power supply to the JBOD Control Board but maintains standby power. To perform most maintenance tasks, unplug the system to remove all power.
Chapter 3: System Interface Information LED Alerts operator to several states, as noted in the table below. Information LED Status Description An overheat condition has occured. Continuously on and red (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan.
SC847 JBOD Chassis Manual Drive Carrier LEDs The SC847 JBOD chassis uses SAS or SATA drives. Each drive carrier has two LED indicators on the front, one blue and red. The LEDs function as follows: Blue Drive Carrier LED Indicator...
Chapter 4: Chassis Setup and Maintenance Chapter 4 Chassis Setup and Maintenance Overview This chapter covers the steps required to install components and perform maintenance on the chassis. The only tool required is a Phillips screwdriver. Review the warnings and precautions listed in the manual before setting up or servicing this chassis.
SC847 JBOD Chassis Manual Power Up/Power Down Sequences There are several procedures to turn on or off the system with the CB3 JBOD control board. Power Up First Use or Power Cord Plug-In 1. Plug the power cords into the rear of the power supplies.
Chapter 4: Chassis Setup and Maintenance Removing Power from the System Before performing most setup or maintenance tasks, use the following procedure to ensure that power has been removed from the system. 1. After the system has completely shut-down, carefully grasp the head of the power cord and gently pull it out of the back of the power supply.
SC847 JBOD Chassis Manual SAS Cables This drawing shows connectors for SAS cabling. For primary and secondary, two connectors are marked In, and two connectors are marked In/Out. Connect two mini-SAS HD cables (SFF-8644) from the head server node host bus adapter (HBA) card to the two Primary receptacles marked In.
Chapter 4: Chassis Setup and Maintenance Cascading Storage The following diagram shows a server with a single host bus adapter (HBA) and requires only the primary expander on the backplane. The SC847 JBOD storage enclosure model E1C can accommodate this configuration. Server with Single...
Page 40
SC847 JBOD Chassis Manual The following diagram shows a server with dual HBAs and requires the primary and secondary expanders on the backplane. The SC847 JBOD storage enclosure model E2C accommodates this configuration. Server with Single Host Bus Adapter (HBA)
Chapter 4: Chassis Setup and Maintenance Removing the Chassis Cover Remove this screw (if necessary) Release Tab Figure 4-6. Removing the Chassis Cover Removing the Chassis Cover 1. Power down the system and remove the power cords from the back of the power supplies.
SC847 JBOD Chassis Manual Installing Hard Drives The drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays. Caution: Except for short periods of time, such as swapping hard drives, do not operate the server with the hard drive bays empty.
Page 43
Chapter 4: Chassis Setup and Maintenance Installing a Hard Drive 1. Remove the two screws securing the dummy drive to the drive carrier and remove the dummy drive. 2. Slide the hard drive into the carrier with the printed circuit board side facing down. Drive Carrier Dummy Drive Figure 4-8.
Page 44
SC847 JBOD Chassis Manual SAS/SATA Hard Drive Drive Carrier Figure 4-9. Installing the Hard Drive into the Drive Carrier 3. Carefully align the mounting holes in both the drive carrier and the hard drive. 4. Secure the hard drive to the carrier using six screws.
Chapter 4: Chassis Setup and Maintenance System Fans Seven heavy-duty hot-swap system fans provide cooling for the chassis. Release Tab Release Tab Figure 4-11. Mid-chassis Fan Figure 4-12. Rear Exhaust Fan Replacing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan has failed.
Page 46
SC847 JBOD Chassis Manual Figure 4-13. Placing a Mid-chassis Fan 4-12...
The chassis features redundant power supplies. They are hot-swappable, meaning they can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are auto-switching capable. This feature enables them to automatically sense the input voltage and operate at a 100-120v or 180-240v.
Chapter 4: Chassis Setup and Maintenance Control Board The JBOD control board (CSE-PTJBOD-CB3) allows the user to remotely control and monitor the chassis resources using the BMC, such as powering on or off, controlling fan speeds and reading temperature data from the backplane. The location is shown in the figure below.
SC847 JBOD Chassis Manual Removing and Installing the Backplanes The SC847 JBOD chassis comes equipped with a BPN-SAS3-846EL1/EL2 front backplane and a BPN-SAS3-827EL1/EL2 rear backplane. For detailed information and instructions on how to change the backplane settings, see Appendices C and D of this manual.
Page 51
Chapter 4: Chassis Setup and Maintenance Removing the Rear Backplane 1. Power down the system and remove the power cords from the rear of the power supplies. Remove the chassis cover as described in Section 4-2. 2. Remove the two side screws (one on each side of the chassis) which secure the rear tray to the chassis.
Page 52
SC847 JBOD Chassis Manual Installing the Front Backplane 1. Confirm that the power cords are still disconnected from the power supplies. 2. Place the front backplane in the chassis. Figure 4-21. Installing the Front Backplane 3. Install the two side screws to secure the front backplane to the chassis.
Page 53
Chapter 4: Chassis Setup and Maintenance Installing the Rear Backplane 1. Confirm that the power cords are still disconnected from the power supplies. 2. Slide the rear tray out of the back of the chassis. Figure 4-23 Installing the Rear Backplane 3.
Chapter 5: Rack Intallation Chapter 5 Rack Installation This chapter provides instructions for preparing and mounting your chassis in a rack. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way.
SC847 JBOD Chassis Manual Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. • In single rack installations, stabilizers should be attached to the rack.
Chapter 5: Rack Intallation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (TMRA).
SC847 JBOD Chassis Manual Installing the Rails There are a variety of rack units on the market, and some may require a slightly different assembly procedure. The following is a basic guideline for installing the system into a rack with the provided rack rails. Also refer to the installation instructions that came with the specific rack you are using.
Chapter 5: Rack Intallation Releasing the Inner Rail Each inner rail has a locking latch. This latch prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing. To mount the rail onto the chassis, first release the inner rail from the outer rails. 1.
SC847 JBOD Chassis Manual Installing the Inner Rails on the Chassis Inner Rails Figure 5-3. Installing the Inner Rails Installing the Inner Rails 1. Identify the left and right side inner rails. Place the correct inner rail on the side of the chassis, aligning the hooks of the chassis with the inner rail holes.
Page 61
Chapter 5: Rack Intallation Warning: Do not pick up the server by the front handles. They are designed to pull the system from a rack only.
SC847 JBOD Chassis Manual Installing the Outer Rails onto the Rack Installing the Outer Rails 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail.
Chapter 5: Rack Intallation Installing the Chassis into a Rack Installing the Chassis into a Rack: 1. Align the chassis rails (A) with the front of the rack rails (B). 2. Slide the chassis rails into the rack rails, keeping the pressure even on both both sides.
SC847 JBOD Chassis Manual Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack. Use a lift.
This manual reflects the revision 1.02 JBOD control board, the most current release available at the time of publication. Refer to the Supermicro web site at www.supermicro.com for the latest updates, compatible parts and supported configurations.
SC847 JBOD Chassis Manual General Safety Guidelines • Always disconnect power cables before installing or removing any components from the computer, including the control board. • Disconnect the power cable before installing or removing any cables from the control board.
3 and 4. Manufacturing Test Connectors Connectors J3 and FB1 are for Supermicro manufacturing use only. 5. BMC LAN LED Header This connector is designated JP6 and is...
SC847 JBOD Chassis Manual 9. PMBus Connector This connector is designated JPI2C1 and connects the power distributor to the Power Management Bus (PMBus). 10. Fan Connectors The fan connectors supply power to the fans and are designated FAN1-FAN10. 11. ATX Power Connector The ATX power connector is designated JPW1.
Page 69
Chapter 6: CB3 JBOD Control Board FAN2 FAN4 FAN5 FAN6 FAN3 FAN10 FAN9 JPW1 1-2:SAS3 2-3:SAS2_847D NMI X PWR LED X NIC1 X OH/FF X RST ON PWR ON Figure 6-3. LED Indicators LED Indicators Description Heartbeat LED: A blinking LED indicates BMC activity Power LED: DC power indicator...
Figure 6-4. SAS I C Cabling (except SC847D) Connections for SC847 JBOD Chassis Specific I C connectors (JP1-JP4) on the JBOD control board are connected to the backplane. C Cable Connections for SC847 JBOD Control Board BPN-SAS3-216EL Backplane SMB connector FAN4 FAN2...
Chapter 6: CB3 JBOD Control Board JBOD Power Up/Power Down Sequences There are several procedures to turn on or off the system with the CB3 JBOD control board. Power Up First Use or Power Cord Plug-In 1. Plug the power cords into the rear of the power supplies. 2.
SC847 JBOD Chassis Manual The control board provides remote access, monitoring and management through the baseboard management controller (BMC) and other management controllers distributed among different system modules. There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: www.supermicro.com/en/solutions/management-software/bmc-resources...
Page 73
Chapter 6: CB3 JBOD Control Board Finding BMC IP Address Using SAS In-band (Linux) An alternate method of finding the IP address: 1. Identify the JBOD enclosure name, for example /dev/sg4. 2. Use the vpd command to view the IP address. [root@hdmaster user]# sg_vpd -p 0x85 /dev/sg4 Management network addresses VPD page: Target device that contains addressed lu, Service type: unspecified...
Appendix A: Power Supply Specifications Appendix A SC847 JBOD Power Supply Specifications This appendix lists power supply specifications for your chassis system. 1200W (Redundant) Supermicro Part # PWS-1K23A-1R with PDB AC Input 100-240 V, 4.5-11 Amp, 50-60 Hz 1000W (100-127Vac) 83A...
Page 78
SC847 JBOD Chassis Manual Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup- port systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to per- form be reasonably expected to result in significant injury or loss of life or catastrophic property damage.
Appendix C BPN-SAS3-846EL Backplane Specifications Appendix C BPN-SAS3-846EL Backplane Specifications To avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. C-1 ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam- age to your system, it is important to handle it very carefully.
Page 80
This manual reflects BPN-SAS3-846EL Revision 1.01, the most current release available at the time of publication. Always refer to the Supermicro Web site at www.supermicro.com for the latest updates, compatible parts and supported con- figurations.
Page 82
SC847E1C/2C JBOD Chassis Manual C-7 Front Connector and Pin Definitions 1. - 2. Primary and Secondary Expander Chips The primary and secondary expander chips allow the backplane to support dual port, cas- cading, and failover configurations. 3. Backplane Power Connectors Backplane Main Power The 4-pin connectors, designated PWR1 -...
Page 83
Appendix C BPN-SAS3-846EL Backplane Specifications C-8 Front Jumper Location and Settings LED Testing Only ACTLED MH14 MH15 Q866 EXP I2C4 MH13 Q872 MH16 EXP I2C0 Q871 LED Testing Only Q870 ACTLED 12V_LED1 P_UART Q873 S_SDB BC57 Q867 BC29 Q869 C177 BC10 P_MDIO P_SDB...
Page 85
Appendix C BPN-SAS3-846EL Backplane Specifications C-10 Rear Connectors and LED Indicators ACT23 ACT5 ACT17 ACT11 ACT23 FAIL5 FAIL23 FAIL17 FAIL11 SAS #11 SAS #5 SAS #23 SAS #17 ACT22 ACT4 ACT16 ACT10 FAIL4 FAIL22 FAIL16 FAIL10 SAS #10 SAS #22 SAS #4 SAS #16 ACT3...
Page 86
SC847E1C/2C JBOD Chassis Manual Rear LED Indicators Rear LED Hard Drive Activity Failure LED SAS #0 ACT0 FAIL0 SAS #1 ACT1 FAIL1 SAS #2 ACT 2 FAIL2 SAS #3 ACT3 FAIL3 SAS #4 ACT4 FAIL4 SAS #5 ACT5 FAIL5 SAS #6 ACT6 FAIL6 SAS #7...
Page 87
Appendix C: BPN-SAS3-846EL Backplane Specifications C-11 Single and Dual Port Expanders SAS primary connectors J49 to J50 and secondary connectors J51 to J52 are bidirectional and can be treated as input or output. Single Ports BPN-SAS3-846EL1 backplanes have a single port expander that accesses all of the drives and supports cascading.
Page 88
SC847E1C/2C JBOD Chassis Manual C-12 Failover The BPN-SAS3-846EL2 model backplane has two expanders which enable effec- tive failover and recovery. Single Host Bus Adapter In a single host bus configuration, the backplane connects to one host bus adapter. SAS HBA MH14 MH15 Q866...
Page 89
Appendix C: BPN-SAS3-846EL Backplane Specifications C-13 Failover with RAID Cards and Multiple HBAs The BPN-SAS3-846EL backplane may be configured for failover with multiple HBAs using either RAID controllers or HBAs to acheive failover protection. RAID Controllers: If RAID controllers are used, then the failover is accomplished through port failover on the same RAID card.
Page 90
SC847E1C/2C JBOD Chassis Manual C-14 Connecting HBAs to the Backplane Connecting an Internal HBA to the Backplane The following section lists the most common cables used to connect the HBA to the backplane. MH14 MH15 Q866 EXP I2C4 MH13 Q872 MH16 EXP I2C0 Q871...
Page 91
Appendix C: BPN-SAS3-846EL Backplane Specifications Cable Name: Internal iPass (Mini-SAS) to HD (Mini-SAS) Part #: CBL-SAST-0508-01 Length: 50 cm (19 inches) Part #: CBL-SAST-0507-01 Length: 80 cm (31 inches) Description: This cable has an iPass (SFF-8087/Mini-SAS) connector (36-pin) at one end and a Mini-SAS HD (SFF-8643) connector at the other end.
Page 92
SC847E1C/2C JBOD Chassis Manual Connecting an External HBA to the Backplane This backplane supports external host bus adapters. In this configuration, the HBA and the backplane are in different physical chassis. This allows a JBOD (Just a Bunch Of Drives) configuration from an existing system. Single External Host Bus Adapter MH14 Q866...
Page 93
Appendix C: BPN-SAS3-846EL Backplane Specifications Connecting Multiple Backplanes in a Single Channel Environment This section describes the cables used when cascading from a single HBA. These connections use CBL-SAST-0531 internal cables and CBL-SAST-0573 external cables. CBL-SAST-0531 (Internal Cable) MH14 MH15 Q866 EXP I2C4 Q872...
Page 94
SC847E1C/2C JBOD Chassis Manual Single HBA Configuration Cables Figure C-15: External Mini-SAS HD to External Mini-SAS HD Cable Cable Name: 1 Meter External Mini-SAS HD to External Mini-SAS HD Cable Part #: CBL-SAST-0573 Ports: Single Placement: External Cable Description: External cascading cable, connects ports between servers and JBODs. Figure C-16: Mini-SAS HD Internal to External Adapter Cable Name: 16-port Mini-SAS HD Internal to External Cable Adapter with LP Bracket...
Page 95
Appendix C: BPN-SAS3-846EL Backplane Specifications Connecting Multiple Backplanes in a Dual Channel Environment This section describes the cables used when cascading from dual HBAs. These con- nections use CBL-SAST-0531 internal cables and CBL-SAST-0573 external cables. MH14 MH15 Q866 EXP I2C4 MH13 Q872 MH16...
Page 96
SC847E1C/2C JBOD Chassis Manual Cascading BPN-SAS3-846EL and BPN-SAS3-847EL For instructions on cascading BPN-SAS3-846EL and BPN-SAS3-847EL together, see page Appendix E of this manual. C-18...
Appendix D: BPN-SAS3-847EL Backplane Specifications Appendix D BPN-SAS3-847EL Backplane Specifications To avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. D-1 ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam- age to your system, it is important to handle it very carefully.
Page 98
This manual reflects BPN-SAS3-847EL Revision 1.00, the most current release available at the time of publication. Always refer to the Supermicro Web site at www.supermicro.com for the latest updates, compatible parts and supported con- figurations.
Page 100
SC847E1C/2C JBOD Chassis Manual D-7 Front Connector and Pin Definitions 1. - 2. Primary and Secondary Expander Chips The primary and secondary expander chips allow the backplane to support dual port, cas- cading, and failover configurations. 3. Backplane Power Connectors Backplane Main Power The 4-pin connectors, designated PWR1 -...
Page 101
Appendix D: BPN-SAS3-847EL Backplane Specifications 11. SMB Connector The SMB connector. is designated SMB (J28). 12. - 13. JTAG Connectors The Primary JTAG connector is designated P_JTAG (J25). The secondary JTAG connec- tor is designated S_JTAG (J35) and is not present on BPN-SAS3-847EL1 backplanes.
Page 102
SC847E1C/2C JBOD Chassis Manual D-8 Front Jumper Location and Settings P_ICE C102 TP31 EC14 P_JTAG 1 2 3 EC20 MH11 MH15 MH17 ACTLED1 BPN-SAS3-847EL2 TP30 MH13 REV:1.00 PRI_J3 DESIGNED IN USA P_HB_LED EC19 EC13 OVERHEATFAIL1 MH16 MH12 MH14 PRI_WWN P_UART PRI_J2 P_SDB C108...
Page 103
Appendix D: BPN-SAS3-847EL Backplane Specifications D-9 Front LED Indicators P_HB_LED 5V_LED1 12V_LED1 P_ICE C102 TP31 EC14 P_JTAG 1 2 3 EC20 MH11 MH15 MH17 BPN-SAS3-847EL2 TP30 MH13 REV:1.00 PRI_J3 DESIGNED IN USA P_HB_LED EC19 EC13 OVERHEATFAIL2 MH16 MH12 MH14 PRI_WWN P_UART PRI_J2 P_SDB...
Page 104
SC847E1C/2C JBOD Chassis Manual D-10 Rear Connectors and LED Indicators ACT13 ACT7 ACT19 FAIL13 ACT13 ACT19 FAIL7 FAIL19 SAS #13 SAS #19 SAS #7 FAIL9 FAIL13 ACT12 ACT6 ACT18 ACT18 FAIL12 ACT12 FAIL6 FAIL18 SAS #6 SAS #12 SAS #18 FAIL12 FAIL8 ACT5...
Page 105
Appendix D: BPN-SAS3-847EL Backplane Specifications Rear LED Indicators Rear LED Hard Drive Activity Failure LED SAS #0 ACT0 FAIL0 SAS #1 ACT1 FAIL1 SAS #2 ACT 2 FAIL2 SAS #3 ACT3 FAIL3 SAS #4 ACT4 FAIL4 SAS #5 ACT5 FAIL5 SAS #6 ACT6 FAIL6...
Page 107
Appendix D: BPN-SAS3-847EL Backplane Specifications D-11 Single and Dual Port Expanders SAS connectors PRI-J1 to J4 and SEC-J1 to J4 are bidirectional and can be treated as input or output. Single Ports BPN-SAS3-847EL1 backplanes have a single port expander that accesses all of the drives and supports cascading.
Page 108
SC847E1C/2C JBOD Chassis Manual D-12 Failover The BPN-SAS3-847EL2 model backplane has two expanders which enable effec- tive failover and recovery. Single Host Bus Adapter In a single host bus configuration, the backplane connects to one host bus adapter. SAS HBA Port A Expander 1 C102 TP31...
Page 109
Appendix D: BPN-SAS3-847EL Backplane Specifications D-13 Failover with RAID Cards and Multiple HBAs The BPN-SAS3-847EL backplane may be configured for failover with multiple HBAs using either RAID controllers or HBAs to acheive failover protection. RAID Controllers: If RAID controllers are used, then the failover is accomplished through port failover on the same RAID card.
Page 110
SC847E1C/2C JBOD Chassis Manual D-14 Connecting HBAs to the Backplane Connecting an Internal HBA to the Backplane The following section lists the most common cables used to connect the HBA to the backplane. C102 TP31 P_ICE EC14 P_JTAG 1 2 3 EC20 MH11 MH15...
Page 111
Appendix D: BPN-SAS3-847EL Backplane Specifications Cable Name: Internal iPass (Mini-SAS) to HD (Mini-SAS) Part #: CBL-SAST-0508-01 Length: 50 cm (19 inches) Part #: CBL-SAST-0507-01 Length: 80 cm (31 inches) Description: This cable has an iPass (SFF-8087/Mini-SAS) connector (36-pin) at one end and a Mini-SAS HD (SFF-8643) connector at the other end.
Page 112
SC847E1C/2C JBOD Chassis Manual Connecting an External HBA to the Backplane This backplane supports external host bus adapters. In this configuration, the HBA and the backplane are in different physical chassis. This allows a JBOD (Just a Bunch Of Drives) configuration from an existing system. Single External Host Bus Adapter P_ICE C102...
Page 113
Appendix D: BPN-SAS3-847EL Backplane Specifications Connecting Multiple Backplanes in a Single Channel Environment This section describes the cables used when cascading from a single HBA. These connections use CBL-SAST-0531 internal cables and CBL-SAST-0573 external cables. CBL-SAST-0531 (Internal Cable) P_ICE C102 TP31 EC14 P_JTAG...
Page 114
SC847E1C/2C JBOD Chassis Manual Single HBA Configuration Cables Figure D-16: External Mini-SAS HD to External Mini-SAS HD Cable Cable Name: 1 Meter External Mini-SAS HD to External Mini-SAS HD Cable Part #: CBL-SAST-0573 Ports: Single Placement: External Cable Description: External cascading cable, connects ports between servers and JBODs. Figure D-17: Mini-SAS HD Internal to External Adapter Cable Name: 16-port Mini-SAS HD Internal to External Cable Adapter with LP Bracket...
Page 115
Appendix D: BPN-SAS3-847EL Backplane Specifications Connecting Multiple Backplanes in a Dual Channel Environment This section describes the cables used when cascading from dual HBAs. These con- nections use CBL-SAST-0531 internal cables and CBL-SAST-0573 external cables. P_ICE C102 TP31 EC14 P_JTAG 1 2 3 EC20 MH11...
Page 116
SC847E1C/2C JBOD Chassis Manual Cascading BPN-SAS3-846EL and BPN-SAS3-847EL For instructions on cascading BPN-SAS3-846EL and BPN-SAS3-847EL together, see page Appendix E of this manual. D-20...