Maintenance, Care & Cleaning (cont.)
Cleaning the Condenser Coil (cont.)
6. Remove the condenser base bolts. See fig. 5.
7. Rotate the front of the condensing unit to the left to allow the
compressor to clear the condensate drain hose fitting.
See fig.6.
8. Carefully slide the condensing unit out (tubing connections are
flexible). Gently blow compressed air or CO₂ through the coil
until it is clean.
9. Carefully vacuum any dirt around and behind the condensing
unit area.
10. Carefully slide the compressor assembly back into position and
replace the bolts. See fig. 7.
11. Reinstall the louvered grill, connect power to the unit, and
verify operation.
Important Warranty Information
THE CLEANING OF THE CONDENSER IS NOT COVERED BY
WARRANTY!
If you have any questions, please contact your local TRUE
Manufacturing Service Department. See the front cover for
locations and contact information.
• Condenser coils accumulate dirt and require cleaning every 30
days or as needed.
• A dirty condenser coil can result in non-warranteed repairs and/
or cabinet failure.
• Proper cleaning involves removing dust from the condenser by
using a soft brush, vacuuming the condenser with a shop vac,
or using CO₂, nitrogen or pressurized air.
• Do not place any filter material in front of the condensing coil.
• On most units, the condenser is accessible by removing the
cabinet's outer grill cover.
• If you cannot remove the dirt adequately, please contact your
licensed refrigeration service provider.
Page 16 of 20
TOAM | OPEN AIR MERCHANDISER
09/25/2020
Fig. 5. Remove the bolts securing the condenser base.
Drain hose fitting.
Fig. 6. Rotate the condensing unit to the left.
Fig. 7. Replace the condenser assembly.