Check Gas Pressure - Monessen Hearth AVFL Series Installation & Operating Instructions Manual

Vent free fireplace system
Hide thumbs Also See for AVFL Series:
Table of Contents

Advertisement

AVFL Vent Free Fireplace

CHECK GAS PRESSURE

Figure 8
Check the gas pressure with the appliance burning.
Open control access door at bottom front of unit to find
valve and regulator referred to below.
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counterclockwise two or three turns
and then place tubing to pressure gauge over test point.
Use test point "A" closest to gas inlet. After taking pressure
reading, be sure and turn captured screw clockwise firmly
to reseal. Do not over torque. Check for gas leaks.
Monessen • AVFL42NIP-SR Installation Instructions • 4119-900 Rev. B • 05/20
14
FIREPLACE INSTALLATION
TEST PORT "A"
Figure 8 –
Pressure Test Point Location