COMMISSIONING
Once the electrical connections are done, have only skilled, qualified staff commission the operator into service.
Before continuing, make sure the area is free of any obstructions, and that there are mechanical, opening and
closing gate stops in place.
Power up and begin configuring the system. Important! Start programming by first doing the following functions:
F54 (opening direction) and F1 (Total Stop). Once the programming is done, verify that the operator and all the
accessories are working properly.Use the < > keys to open and close the gate and ESC to stop it.
⚠ After powering up the system, the first maneuver is always the opening. In this phase, the gate cannot be
closed. You will need to wait for the gate to completely open.
⚠ Immediately press the STOP button if any suspicious malfunctions, noises or vibrations occur in the system.

MANAGING USERS

 When adding and deleting users, the flashing numbers appearing are those numbers that are available and
usable to assign to a new user (max. 250 users).
 Before registering the users, make sure the AF radio card is plugged into the connector (see the paragraph
called CONTROL DEVICES).