Fujitsu ASYG07KMTA Service Manual page 94

Indoor/outdoor split type room air conditioner / wall mounted type
Hide thumbs Also See for ASYG07KMTA:
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 2
Inverter Compressor
Check Point 1 : Check Connection
Check terminal connection of Compressor
(loose or incorrect wiring)
Check Point 2 : Check Winding Resistance
Check winding resistance of each terminal
If the resistance value is 0
W(C)
U(R)
Check Point 3 : Replace Main PCB
If the symptom does not change with above Check 1, 2, replace Main PCB.
Terminal cover opened
(
)
W
C
(BLACK)
U(R)
(RED)
or infinite, replace Compressor.
V(S)
V(S)
(WHITE)
Resistance Value :
2.18
at 20°C for 07/ 09/ 12KMTA
1.975 at 20°C for 14KMTA
02-33