Table of Contents

Advertisement

4.2

Connecting

Installing the bus connector
Install the PROFINET connector according to the instructions in the PROFINET Installation
Guide (https://www.profibus.com/).
Tools required
3 to 3.5 mm screwdriver, alternatively TX10 (torx).
Accessories required
• Connector:
– IE FC RJ45 plug 180 2X2 (6GK1901-1BB10-2A)
– IE FC RJ45 plug 180 4X2 (6GK1901-1BB12-2A)
• Cables:
– IE FC TP standard cable (6XV1840-2A)
– IE FC TP trailing cable (6XV1840-3AH10)
– IE FC TP Marine Cable (6XV1840-4AH10)
– IE FC TP robust cable (6XV1841-2)
– IE TP torsion cable (6XV1870-2F)
• Please observe the specifications in the PROFINET Installation Guide
(https://www.profibus.com/).
Pin assignment
The following table shows the signal name and description of the pin assignment of the
BusAdapter BA 2×RJ45.
Table 4- 1
BusAdapter
Equipment Manual, 08/2020, A5E41449003-AB
PROFINET IO pin assignment with BusAdapter BA 2×RJ45
View
1
2
3
4
5
6
7
8
Signal name
TD
Transmit Data +
TD_N
Transmit Data –
RD
Receive Data +
TERM1
Termination Network 1
TERM1
Termination Network 1
RD_N
Receive Data –
TERM2
Termination Network 2
TERM2
Termination Network 1
BusAdapter BA 2xRJ45