General Information

The CXH series heaters rated 3 through 35 kW are designed
for operation in Category 2, group IIB, hazardous gas atmo-
spheres having an ignition temperature of 200°C (392°F) or
higher. They are designed for comfort heating and should not
be operated in ambient temperatures less than -20°C (-4°F)
or greater than 40°C (104°F). The units are easily adapted for
wall, ceiling or pole mounting. Refer to Figure 4 on Page 3 for
mounting information.

Installation

FIRE/EXPLOSION HAZARD. Mount only in upright po-
sition and observe nameplate mounting clearances.
Heater Location instructions:
Arrange units so their discharge air streams:
A. are subjected to a minimum of interference from col-
umns, machinery and partitions.
B. wipe exposed walls without blowing directly at them.
C. are directed away from room occupants in comfort heating.
D. are directed along the windward side when installed in a
building exposed to a prevailing wind.
Locate thermostat on interior partition walls or posts away
from cold drafts, internal heat sources and away from heater
discharge air streams.
Small rooms can be heated by one unit heater. Where two
walls are exposed, the heater should be mounted as shown
in Figure 2. Large rooms require multi-unit installations. Num-
ber and capacity of units will be determined by volume of
building and square feet of floor area to be heated. Arrange
units to provide perimeter air circulation where each unit sup-
ports the air stream from another.
The CXH-C/D hazardous location heaters are designed for
use only in a permanently mounted upright position. We rec-
ommend the use of a mounting kit (ceiling, wall or pole) avail-
able from Chromalox. (Figures 5, 6 and 7)
They are supplied with either 24 or 120V internal control cir-
cuit voltage. The heater is designed for use with an external
hazardous location thermostat or optional built-in thermostat.
The standard heater is designed to operate up to 7500
feet (2,286 m) altitude. Consult factory for specific rec-
ommendations when using the units at higher altitudes.
The ceiling or wall mounting surface and the anchoring provi-
sion must be sufficient to support the combined weights of
the unit and mounting hardware.
If using mounting hardware or a supporting structure not
supplied by Chromalox, the unit should be suspended from
the supporting structure thru the two mounting points on
top of the unit with 5/8 NC bolts and lockwashers. If single
point mounting is desired, order the correct size Chromalox
adapter bracket (P/N 027-302361-001 for 12" fan units, P/N
027-302361-002 for 16" fan units) and P/N 027-302361-003
for 20" fan units. This bracket is designed to hold the unit
over its center of gravity with a 1 dia. bolt. The maximum tilt
angles as shown in Figure 3 must not be exceeded in either
direction during operation and installation.
Failure to comply will cause high limit shut down.