Night Set Mode - Daikin CTXG09QVJUW Service Manual

Multi-split type air conditioners 2/3mxl-q series
Hide thumbs Also See for CTXG09QVJUW:
Table of Contents

Advertisement

CTXG, CTXS, FTXS, CDXS, FDXS, FVXS Series Functions
CTXS, FTXS series
CDXS, FDXS, FVXS series
Refer to Temperature Control on page 37 for details.
2.6

NIGHT SET Mode

Outline
When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Details
NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in cooling, or lowers it slightly in heating. This
prevents excessive cooling or heating to ensure comfortable sleeping conditions, and also
conserves electricity.
Cooling
Heating
48
Zone A
2.0˚C (3.6˚F)
Zone B
1.5˚C (2.7˚F)
Zone C
Zone A
Zone B
1.0˚C (1.8˚F)
Zone C
Target temperature
TIMER operation
NIGHT SET Mode ON
Target temperature
TIMER operation
NIGHT SET Mode ON
Room thermistor temperature – target temperature
OFF
2.0˚C (3.6˚F)
1.0˚C (1.8˚F)
0.5˚C (0.9˚F)
ON
Room thermistor temperature – target temperature
OFF
1.5˚C (2.7˚F)
0˚C (0˚F)
ON
0.5˚C (0.9˚F)
1 hour
+0.5˚C (+0.9˚F)
temperature shift
2˚C (3.6˚F)
1 hour
–2˚C (–3.6˚F)
temperature shift
SiUS121632EA
(R24033)
(R24034)
Operation stops
at the set hour
Functions and Control
(R23917)
(R23918)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents