1. USING THE LCD PANEL (BASIC OPERATIONS)

1-2. Parameter setting method

Parameter settings are made at the sewing operation screen.
* For details on the sewing data reading method, refer to "3. Using storage media".
* For details on memory switch setting methods, refer to "2-1. Memory switch setting method".
Sewing speed
Use the Speed △ and ▽ keys (1) to make the setting.
・Setting range: 200 sti/min to corresponding value in the table below
100 sti/min units Initial value: 2,000 sti/min
Table: Maximum sewing speed for each model
Models other than those below
BAS-326H-484
BAS-360H/BAS-365H
Digital tension
Touch the Tension △ or ▽ key (2) to change the tension value.
・Setting range: 0 to 300 or 0 to 500 (for BAS-360H and BAS-365H)
Initial value: For -3 specifications, 100
Thread wiping
Touch the Wiper key (3) to turn the wiper on or off. (The initial value varies for each model and specification.)
When the setting is on, the key is displayed in blue.
4
2800 sti/min
2200 sti/min
2700 sti/min
For -5 and -7 specifications, 160
BAS H series
(1)
(2)
(3)
(4)
(5)