System Layout 8 - Viessmann VITODENS 200-W Installation Instructions Manual

Viessmann vitodens 200-w, wb2b series wall-mounted, gas-fired condensing boiler
Table of Contents

Advertisement

Boiler Connections
Installation Examples

System layout 8

Vitodens 200-W, WB2B with...
– DHW storage tank
– low-loss header
– multiple heating circuits with mixing valves
P
A
M
PRV
TPV
L
5
O
K
Fig. 30
When designing a system as illustrated above, please contact your local Viessmann Sales Representative for assistance.
Legend
AV Air vent (WB2B models 45, 60)
PRV Pressure relief valve
TPV Temperature and pressure relief valve
Vitodens 200-W WB2B boiler with
Vitotronic 200, HO1 outdoor reset
control
Outdoor temperature
Boiler pump sÖ*
Vitocontrol or Vitotronic 200-H,
Mixing valve temperature sensor
Heating circuit pumps
Accessory kit for heating circuit with
*2
mixing valve
Heating circuits with mixing valves
I
Viessmann temperature sensor for
low-loss header
Low-loss header
J
DHW circulating pump sA*
DHW tank temperature sensor
36
(continued)
D
B
1
H
AV
E
2
F
Q
C
I
5
G
J
N
DHW storage tank
Expansion tank
O
DHW recirculation pump sK*
P
Power/Pump module
Q Flow check valve
* See pages 53 and 57
*1
Contact your local Sales Representative
for details.
*1
*2
Vitotronic 200-H, HK1M mixing valve
control with LON communication module
can be used instead of the accessory kit
and Vitocontrol.
H
H
E
E
2
2
F
F
G
G
IMPORTANT
Please note location of expansion tank
and flow check valve Q.
IMPORTANT
Pumps
Vitodens 200-W WB2B boiler (as
illustrated).
and
must pump into the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wb2b 45Wb2b 60

Table of Contents