Alignment
Software Alignment/Confirmation Mode
The "Software Alignment/Confirmation Mode" has been
build in the microprocessor in order to adjust and con-
firm the performance of transceiver.
The purpose is to adjust transceiver simply and to con-
firm the performance of transceiver smoothly.
S
S
A
TARTING
OFTWARE
LIGNMENT
Confirm that the transceiver's power is turned off.
Short the TEST points (JP1001).
Press and hold the VOL/PWR knob until the radio
turns on while press and holding the [ CALL ( MENU )]
and [ DISTRESS ] keys. The LCD
will be as shown in the illustration
at the right.
Squelch Adjustment
Setup the test equipment as shown below.
RF Signal
Generator
Press the [ SCAN ( MEM )] key to re-
call the Alignment Item "04:
THRESHOLD
THRESHOLD
THRESHOLD."
THRESHOLD
THRESHOLD
Set the RF Signal Generator output to 156.800 MHz,
at a level of –10 dBμV, ±3.0 kHz deviation with a 1
kHz audio tone.
Press the [ DW ( IC )] key.
Press the [ ENT ] key to save the new setting.
Press the [ SCAN ( MEM )] key to re-
call the Alignment Item "05: TIGHT
Set the RF Signal Generator output
to 156.800 MHz, at a level of +2 dBμ ±3.0 kHz devia-
tion with a 1 kHz audio tone.
Press the [ DW ( IC )] key.
Press the [ ENT ] key to save the new setting.
Press the [ SCAN ( MEM )] key to re-
call the Alignment Item "07: DC
VOLT."
VOLT
VOLT
VOLT
VOLT
Set the DC Power Supply to 13.8 V.
Press the [ DW ( IC )] key.
Press the [ ENT ] key to save the new setting.
This completes the Software Alignment Mode. To save
all settings and exit, press and hold the [ DISTRESS ] key
for 2 seconds.
14
M
ODE
GX3000S/E
ANT
04:
04:
04:
04:
05: TIGHT
05: TIGHT."
05: TIGHT
05: TIGHT
07: DC
07: DC
07: DC
07: DC
S
S
C
TARTING
OFTWARE
ONFIRMATION
Confirm that the transceiver's power is turned off.
Short the TEST points (JP1001).
Press and hold the VOL/PWR knob until the radio
turns on while press and holding the [ DW ( IC )] and
[ DISTRESS ] keys. Release the
keys, the LCD will be as shown for
one second in the illustration at the
right.
DSC Encoder Confirmation
Setup the test equipment as shown below.
Sampling
Coupler
50-ohm
Dummy Load
Deviation
Meter
Set the channel to CH70.
Press the PTT switch, confirm that the first tone de-
viation is 4.2 kHz ±0.3 kHz.
Note: In CH70 while Software Confirmation Mode,
ever time you are in transmit mode, (every time you
press PTT), the following test tone can be outputted:
1st transmission: Synthetic tone of 1300 Hz and 2100 Hz
2nd transmission: 1300 Hz
3rd transmission: 2100 Hz
4th transmission: No Modulation
5th transmission: Return to 1st transmission
This completes the Software Alignment/Confirmation
Mode. Turn the transceiver's power off, then disconnect
the Jumper from the TEST points (JP1001).
M
ODE
GX3000S/E
ANT