DATA

6-1. REFILLING REFRIGERANT CHARGE (R410A : kg) PUHZ-ZRP35-140

PUHZ-ZRP140VKA

PUHZ-ZRP140YKAR1
6-2. COMPRESSOR TECHNICAL DATA
Service Ref.
Compressor model
U-V
Winding
U-W
Resistance
(
)
W-V
Service Ref.
Compressor model
U-V
Winding
U-W
Resistance
(
)
W-V
OCH527B
10m
20m
1.8
2.0
2.0
2.2
3.1
3.3
3.1
3.3
4.6
4.8
4.6
4.8
4.6
4.8
PUHZ-ZRP35VKA
SNB092FGCM
0.64
0.64
0.64
PUHZ-ZRP71VHA
SNB172FSHM1
1.34
1.34
1.34
Piping length (one way)
30m
40m
50m
2.2
2.4
2.6
2.4
2.6
2.8
3.5
4.1
4.7
3.5
4.1
4.7
5.0
5.6
6.2
5.0
5.6
6.2
5.0
5.6
6.2
Additional charge is required for pipes longer
than 30 m.
PUHZ-ZRP50VKA
SNB130FGCM2
0.64
0.64
0.64
PUHZ-ZRP100/125/140VKA
ANB33FNFMT
0.466
0.466
0.466
9
60m
75m
-
-
-
-
-
-
-
-
6.8
7.4
6.8
7.4
6.8
7.4
(at 20°C)
PUHZ-ZRP60VHA
SNB130FGCM1
0.64
0.64
0.64
(at 20°C)
PUHZ-ZRP100/125/140YKA
PUHZ-ZRP100/125/140YKAR1
ANB33FNCMT
1.20
1.20
1.20
Initial
charged
2.2
2.4
3.5
3.5
5.0
5.0
5.0