Technical Data - Viessmann Vitodens 200-W B2HA 80 Installation Instructions Manual

Wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for Vitodens 200-W B2HA 80:
Table of Contents

Advertisement

Additional Information

Technical Data

Boiler Model No. B2HA
CSA input Natural Gas (NG)
CSA input Liquid Propane Gas (LPG)
CSA output NG
CSA output LPG
DOE/AHRI Gross output
Net AHRI Rating *4
Heat exchanger surface area
Min. gas supply pressure
Natural gas
Liquid propane gas
Max. gas supply pressure *2
Natural gas
Liquid propane gas
ANSI Z21,13/CSA 4.9
Thermal efficiency
AHRI, BTS-2000 *B
Combustion efficiency
Thermal efficiency
A.F.U.E.
Weight
Boiler water content
Boiler max. flow rate *3
Max. operating pressure
at 210ºF (99ºC)
Boiler water temperature
- Adjustable high limit (AHL) range
space heating (steady state)
DHW production
- Fixed high limit (FHL)
Boiler connections
Boiler heating supply and return
Pressure relief valve
Drain valve
Boiler supply/return for
indirect-fired DHW storage tank
(field supplied)
Gas valve connection
*A
For high altitude installations 5,000 - 10,000 ft. (1500 m - 3000 m), the input for model B2HA 100, 352 will have an
altitude de-ration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m) average of 2.8% / 1,000 ft. (305 m).
*B
Tested to AHRI, BTS-2000 Testing Standard Method to Determine Efficiency of Commercial Heating Boilers.
*1
Output based on 140ºF (60ºC), 120ºF (49ºC) system supply/return temperature.
*2
If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator
must be installed upstream of the heating system.
*3
See "Waterside Flow" on page 30 of this manual.
*4
Net AHRI rating based on piping and pick-up allowance of 1.15.
*5
Output based on 180ºF (82ºC), 80ºF (26ºC) system supply/return temperature.
60
Vitodens 200-W B2HA 80 to 100, 285 to 352 Installation
80, 285
MBH
71-285
(kW)
(21-83)
MBH
104-285
(kW)
(30-83)
MBH
*1 65-260
(kW)
(19-76)
MBH
*1 95-260
(kW)
(28-76)
MBH
--
(kW)
--
MBH
226
(kW)
(66.2)
2
ft.
28.88
2
(m
)
(2.68)
"w.c.
4
"w.c.
10
"w.c.
14
"w.c.
14
%
--
%
--
%
--
%
92.0
lbs
194
(kg)
(88)
USG
3.4
(L)
(12.8)
GPM
25
(L/h)
(5700)
psig
60
bar
4
ºF
68 to 185
(ºC)
(20 to 85)
ºF
185
(ºC)
(85)
ºF (ºC)
210 (99)
1
b in.
NPTM
¾
NPTF
in.
(male
¾
in.
thread)
1
b in.
NPT
NPTF
1 in.
88, 311 *A
100, 352 *A
71-311
(21-91)
104-311
(30-91)
*5 67-294
*5 67-333
(20-86)
*5 98-294
*5 98-333
(29-86)
292
(85)
254
(74)
28.88
(2.68)
4
10
14
14
94.5
94.2
94.0
--
194
(88)
3.4
(12.8)
25
(5700)
60
4
68 to 185
(20 to 85)
185
(85)
210 (99)
1
b in.
¾
in.
¾
in.
1
b in.
1 in.
71-352
(21-103)
104-311
(30-91)
(20-98)
(29-98)
329
(96)
286
(84)
28.88
(2.68)
4
10
14
14
94.5
94.0
93.5
--
194
(88)
3.4
(12.8)
25
(5700)
60
4
68 to 185
(20 to 85)
185
(85)
210 (99)
1
b in.
¾
in.
¾
in.
1
b in.
1 in.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w b2ha 88Vitodens 200-w b2ha 100