Sanyo SPW-D253GH56 Service Manual page 81

Split system
Hide thumbs Also See for SPW-D253GH56:
Table of Contents

Advertisement

2)
Compressor motor does not operate.
Does compressor motor magnetic
contactor (52C) actuate ?
Check resistance of compressor
motor winding.
Replace the compressor.
3)
Outdoor fan does not operate.
Are auxiliary relays (1Y, 2Y)
normal ?
Is fan motor capacitor normal ?
Is there voltage output of
P.C.B. Ass'y for fan motor ?
Check resistance of fan motor
winding.
Replace the fan motor.
No
Yes
NG
No
Yes
No
Yes
No
Yes
NG
– 81 –
4. Service procedures
Replace the compressor
motor magnetic contactor.
0461_M_I
Replace the relays.
Replace the capacitor.
Replace P.C.B. Ass'y
in the outdoor unit.
4
0462_M_I
SM830036