OpTIONAL REMOTE
OpERATION
Note: The WRC receiver and hand-held re-
mote control kit must be purchased separately
(see Accessories, page 35). Follow installa-
tion instructions on page 26.
1. Turn equipment shutoff valve to ON posi-
tion. You can now turn burner on and off
with hand-held remote control unit.
IMPORTANT: Be sure to press ON/OFF
buttons on hand-held remote control unit
for up to 3 seconds to assure proper
operation.
2. Press ON/OFF button to turn burner on
and off.
OpERATING OpTIONAL
BLOWER ACCESSORY
Locate blower controls by opening lower
louver panel on fireplace. Blower controls are
Check pilot flame pattern and burner flame
patterns often.
pILOT ASSEMBLY
The pilot assembly is factory preset for the
proper flame. Alterations may have occurred
during shipping and handling. The pilot is
located on left hand side of burner.
The flame must envelope 1/4" of top of the
ignitor/sensor and grounding stem.
If your pilot assembly does not meet these
requirements:
• Turn adjustment screw marked PILOT
clockwise to decrease or counterclockwise
to increase flame to proper size (see Figure
42, page 28). Do not remove adjustment
screw.
• see Troubleshooting, page 31
Pilot
Burner
Figure 44 - Correct Pilot Flame Pattern
116240-01J
OPERATION
Continued

INSPECTING bURNERS

Sensing
Rod
Ignitor/
Sensor
www.desatech.com
located on the left side of switch bracket to
the right just inside louver panel.
The BK manual blower and BKT thermostati-
cally-controlled blower have an ON setting
and an OFF setting. Blower will only run when
switch is in the ON position. In the OFF posi-
tion, blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for fireplace, your fireplace
and blower will not turn on and off at the same
time. Fireplace may run for several minutes
before blower turns on. After heater modulates
to the pilot position, blower will continue to run.
Blower will shut off after firebox temperature
decreases.
The blower helps distribute heated air from
fireplace. Periodically check louvers of firebox
and remove any dust, dirt or other obstruc-
tions that will hinder the flow of air.
BURNER FLAME pATTERN
Burner flames will be steady, not lifting or float-
ing. Flame patterns will be different from unit
to unit and will vary depending on installation
type and weather conditions.
If the vent configuration is installed incorrectly,
flames will lift or "ghost". This can be danger-
ous. Inspect flames after installation to ensure
proper installation and performance.
Figure 45 shows a typical flame pattern.
If burner flame pattern differs from that de-
scribed:
• turn fireplace off (see To Turn Off Gas to
Appliance, page 28)
• see Troubleshooting, page 31
Figure 45 - Typical Flame Pattern
29