VENTING INSTALLATION
Continued
WARNING: Do not recess
vent termination into any wall.
This will cause a fire hazard.
6. Noncombustible Exterior Wall: Posi-
tion horizontal vent cap in center of 8
round hole and attach to exterior wall with
four wood screws provided (see Figure
10). Before attaching vent cap to exterior
wall, run a bead of non-hardening mastic
(pliable sealant) around outside edges to
make a seal between it and outside wall.
Note: Four wood screws provided should
be replaced with appropriate fasteners
for stucco, brick, concrete or other types
of sidings.
Combustible Exterior Wall: For vinyl
siding, stucco or wood exteriors, a siding
standoff may be installed between vent
cap and exterior wall. Siding standoff
prevents excessive heat from damaging
siding materials. Siding material must be
cut to accommodate standoff. Bolt vent
cap to standoff. Apply non-hardening
mastic around outside edge of standoff.
Position standoff/cap assembly in center
of the 11
/
" square hole and attach to
1
2
exterior wall with wood screws provided
(see Figure 11). Siding standoff must sit
flush against exterior fascia material.
7. Connecting Vent Cap with Horizontal
Vent Pipe: Slide wall firestop over the
vent pipe before connecting horizontal
run to vent cap (see Figure 12).
Carefully move fireplace, with vent as-
sembly attached, toward wall and insert
vent pipe into horizontal termination. Pipe
overlap should be a minimum of 1
Figure 13, page 12).
Slide wall firestop against interior wall
surface and attach with screws provided.
See Figure 13, page 12, for horizontal
termination details.
Place fireplace into position and shim with
noncombustible material if needed. Nail or
screw side flanges to framing to secure
unit in place. IMPORTANT: Make sure fire-
place is level before securing. If fireplace
is not level it will not work properly.
116240-01J
/
"
1
2
Figure 10 - Installing Horizontal Vent Cap
Apply Mastic to
All Four Sides
Figure 11 - Installing Siding Standoff
/
" (see
1
4
Vent Cap
(Horizontal
Termination)
Figure 12 - Connecting Vent Cap with
www.desatech.com
(Noncombustible Exterior)
Cut Siding Away to
Fit Standoff
Standoff
(Combustible Exterior Wall)
Screw
Horizontal Vent Pipe
Apply Mastic to
All Four Sides
Vent Cap
Wood Screw
Wood
Screw
Vent
Cap
Screws
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

(v)kc42pe series

Table of Contents