16. Remote start Safelock
1.
Off: the Door lock and Factory Alarm Re-arm outputs will maintain the current status (locked/un-
locked) during remote start and after shut down
2.
On: the Door lock and Factory Alarm Re-arm outputs will arm/lock the vehicle during remote start
and after shutdown

Bitwriter - Only Options

If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine
has previously been locked, it must be unlocked with Bitwriter® - this cannot be done manually with
the Control button.
The Bitwriter®
gives you access to a wider range of system options. These features and the adjustments
that may be programmed are described in the table below.
Menu
Feature
Item
1
Aux/Trunk Icon Type*
2
Aux 1 Timed Output
3
Aux 1 Icon Type*
4
Aux 2 Timed Output
5
Aux 2 Icon Type*
6
Aux 3 Timed Output
7
Aux 3 Icon Type*
8
Aux 4 Timed Output
9
Diesel Start Delay
type (seconds)
10
Timer Mode Runtime
(minutes)
11
Timer Mode Starts
12
Timer mode intervals
(hours)
13
Smart start low temp
14
Smart start high temp
15
Smart start low bat-
tery (volts)
16
Starter Release Fine
Tune
17
Feature Programming
18
Transmitter Program-
ming
19
Remote Start Runtime
20
Virtual Tach Fine Tune
* Not available on the LE 2-way or 1-way remote
© 2009 Directed Electronics. All rights reserved.
Default
Opt. 2
Opt. 3
Trunk
Window
Sunroof
30 sec.
Options: 1 to 90 sec.
Pulsed
Trunk
Window
Options: 1 to 90 sec.
30 sec.
Trunk
Window
Pulsed
30 sec.
Options: 1 to 90 sec.
Pulsed
Trunk
Window
Options: 1 to 90 sec.
30 sec.
Options: 1 to 90 sec.
15 sec.
12 min.
Options: 1 to 16 min.
6 starts
Options: 1/2/3/4 to 24 (Starts) in increments of 2
Options: 1/2/3/4 to 24 in 2 hour increments
3 hr.
Options: OFF, -20° to 70° in 10° increments
0° (F)
Options: OFF, 40° to 130° in 10° increments
100° (F)
10.5V
Options: OFF, 9V to 12.5V in 0.5V increments
6
Options: 0 to 20 in increments of 1
(normal)
Unlocked
Locked
Unlocked
Locked
12 min.
Options: 1 to 60 min.
Not Ini-
Options: Not initialized, 0 to 1000 in 50 millisecond increments
tialized
Opt.4
Opt. 5+
Audio
Lights/Left dr/Right dr/Rear Hatch
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
Sunroof
Audio/Lights/Left dr/Right dr/Rear Hatch/
Timed/Latched
17