Pc Control Of The Tv - Sharp LC-70LE735M Operation Manual

Aquos lcd colour television
Table of Contents

Advertisement

Connecting a PC

PC control of the TV

• When a programme is set, the TV can be controlled
from the PC using the RS-232C or IP. The input
signal (PC/video) can be selected, the volume can be
adjusted and various other adjustments and settings
can be made, enabling automatic programmed
playing.
• Use an RS-232C serial control cable (cross type),
ETHERNET cable (commercially available) or wireless
LAN USB adapter for the connections.
NOTE
• This PC control should be used by a person who is
accustomed to using PCs.
Communication conditions for IP
LAN
ETHERNET cable
(commercially available)
Connect to the TV with the following settings made for IP
on the PC.
IP protocol
TCP/IP
Host IP address
Set the IP address on the TV menu.
Service
None (do not select Telnet or SSH).
Set a port number on the TV menu
TCP port#
(Control port).
When you set your ID and password on the TV menu,
you need to enter them as soon as you connect to the
TV.
NOTE
• The connection will be cut off when there has been no
communication for 3 minutes.
View setting
IP Control setup
1
Go to "HOME" > "TV Menu" > "Setup" > "View
setting" > "Network setup" > "IP Control setup" >
select "Change".
2
To use IP Control, select "Enable".
3
Set the device name.
4
Set your login ID and password.
5
Set the port to use with IP Control.
6
Confirm the settings, and press c/d to select
"OK" and then press A.
Communication conditions for RS-232C
RS-232C serial control cable (cross type)
(commercially available)
Set the RS-232C communications settings on the PC
to match the TV's communications conditions. The TV's
communications settings are as follows:
Baud rate
Data length
Parity bit
Stop bit
Flow control
Communication procedure
Send the control commands from the PC via the RS-
232C connector.
The TV operates according to the received command
and sends a response message to the PC.
Do not send multiple commands at the same time. Wait
until the PC receives the OK response before sending
the next command.
Make sure to send "A" with the carriage return and
confirm that "ERR" returns before operating.
Command format
Eight ASCII codes +CR
C1 C2 C3 C4 P1 P2 P3 P4
Command four digits: Command. The text of four
characters.
Parameter four digits: Parameter 0_9, blank, ?, minus
Return code (0DH): ?
Parameter
Input the parameter values, aligning left, and fill with
blank(s) for the remainder (be sure that four values are
input for the parameter).
When the input parameter is not within an adjustable
range, "ERR" returns (refer to "Response code format").
0
0
1
0
When "?" is input for some commands, the present
setting value responds.
?
Response code format
Normal response
O
K
Return code (0DH)
9,600 bps
8 bits
None
1 bit
None
0
0
9
0
0
0
5
5
?
?
?
Problem response
(communication error or
incorrect command)
E
R
R
Return code (0DH)
47