Samsung WF361 series Technical Information page 5

Hide thumbs Also See for WF361 series:
Table of Contents

Advertisement

Available languages

Available languages

ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
Definition of Quick Test Mode:
- Check operation of all LED's (Verify faulty LED).
- Check model and software version.
- Check different operating modes (e.g. water valve, motor, door, drain pump, etc.).
How to Enter:
- Plug in the unit.
- Press Soil Key, Spin Key and Power Key at the same Time.
Quick Test Mode:
EEPROM Clear Check
Definition of EEPROM Clear Mode:
- EEPROM initialization.
- All course/option settings are to be reset to default
values after EEPROM initialization.
- When Service arises and it needs PCB replacement,
EEPROM should be reset.
How to Enter:
- The unit needs to be on.
- Press Delay Start Key, and Power Key at the same
time.
[BIGBANG]Technical_information-03207A-03_EN.indd 5
WARNING
1. A ll LED's light up and it sends out Beep Sound when it
enters into the Quick Test Mode. (Including 7-Segment)
2. Displays software version for a sec and Clear EEprom. (Ex. If
S/W Version is 04, 7-Segment will display Ud04)
3. W hen the version is displayed, turn the Jog-Dial so that
the version disappears. Press the following keys to test the
various components.
- Temp Key : Water Valve Test
- Spin Key : Door Lock/Unlock Test
- Soil Key : Water Heater Test
- Signal : Drain Pump Test
5
2013-7-16 17:15:04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wf363 seriesWf365 seriesWf364 series

Table of Contents