Electrical Requirements - Electric Dryer (Canada Only) - Maytag MDE17PR Installation Instructions Manual

Commercial dryer – gas or electric
Table of Contents

Advertisement

Available languages

Available languages

If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
I Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
I 10-gauge solid copper wire (do not use aluminum).
I At least 5 ft (1.52 m) long.
Electrical Requirements – Canada Only
It is your responsibility
I To contact a qualified electrical installer.
I To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-latest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3
CANADA.
I To supply the required 4 wire, single phase, 120/240 volt, 60
Hz., AC only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch
circuit.
I This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure
wall receptacle is within reach of dryer's final location.
4-wire receptacle (14-30R)
I Do not use an extension cord.
If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number 9831317. For further information, please
reference the service numbers located in the "Assistance
or Service" section.