Download Print this page
Sharp AY-XP9GHR Service Manual
Hide thumbs Also See for AY-XP9GHR:

Advertisement

TopPage
[1]
SPECIFICATION.................................... . ....... 1-1
[2]
EXTERNAL DIMENSION....................... . ....... 1-3
[3]
WIRING DIAGRM .................................. . ....... 1-4
[4]
ELECTRICAL PARTS ............................ . ....... 1-4
CHAPTER 2. EXPLAMATION OF CIRCUIT AND OP-
ERATION
[1]
BLOCK DIAGRAMS............................... . ....... 2-1
[2]
MICROCOMPUTER CONTROL SYSTEM
[3]
FUNCTION............................................. . ....... 2-8
CHAPTER 3. FUNCTION AND OPERATION OF PRO-
TECTIVE PROCEDURES
[1]
PROTECTION DEVICE FUNCTIONS AND
OPERATIONS........................................ . ....... 3-1
[2]
AIR CONDITIONER OPERATION IN
THERMISTOR ERROR ......................... . ....... 3-3
[3]
THERMISTOR TEMPERATURE CHAR-
ACTERISTICS ....................................... . ....... 3-5
[4]
HOW TO OPERATE THE OUTDOOR
UNIT INDEPENDENTLY........................ . ....... 3-6
[5]
GENERAL TROUBLESHOOTING CHART
Parts marked with "
" are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
SERVICE MANUAL
SPLIT TYPE
ROOM AIR CONDITIONER
INDOOR UNIT
MODELS
AY-XP9GHR
AY-XP12GHR
In the interests of user-safety (Required by safety regulations in some countries) the set should be
restored to its original condition and only parts identical to those specified should be used.
CONTENTS
........ 2-3
........ 3-6
OUTDOOR UNIT
AE-X9GHR
AE-X12GHR
[6]
MALFUNCTION (PARTS) CHECK METH-
OD .................................................................3-8
[7]
OUTDOOR UNIT CHECK METHOD...........3-10
[8]
TROUBLESHOOTING GUIDE ....................3-13
REPLACEMENT PARTS LIST
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
AYXP9GHR

Advertisement

loading

Summary of Contents for Sharp AY-XP9GHR

  • Page 1: Table Of Contents

    SPLIT TYPE ROOM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT MODELS AY-XP9GHR AE-X9GHR AY-XP12GHR AE-X12GHR In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2: Chapter 1. Specification

    AYXP9GHR Service Manual AYXP9GHR CHAPTER 1. SPECIFICATION [1] SPECIFICATION 1. AY-XP9GHR – AE-X9GHR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP9GHR AE-X9GHR Cooling capacity(Min. - Max.) 2.50 (0.9 - 3.0) Heating capacity(Min. - Max.) 3.20 (0.9 - 5.0) Moisture removal(at cooling)
  • Page 3 AYXP9GHR 2. AY-XP12GHR – AE-X12GHR MODEL INDOOR UNIT OUTDOOR UNIT ITEMS AY-XP12FR-N AE-X12FR-N Cooling capacity(Min. - Max.) 3.5 (0.9 - 4.0) Heating capacity(Min. - Max.) 4.2 (0.9 - 6.0) Moisture removal(at cooling) Liters/h Electrical data Phase Single Rated frequency Rated voltage Rated current ✩...
  • Page 4: External Dimension

    AYXP9GHR [2] EXTERNAL DIMENSION 1. Indoor unit 18.5 INVERTER AIR CONDITIONER 22.0 2. Outdoor unit 37.5 1 – 3...
  • Page 5: Wiring Diagrm

    AYXP9GHR [3] WIRING DIAGRM 1. Indoor unit 2. Outdoor unit [4] ELECTRICAL PARTS 1. Indoor unit DESCRIPTION MODEL REMARKS Indoor fan motor MLB084 DC Motor Indoor fan motor capacitor – – Transformer – – FUSE1 – QFS-GA062JBZZ (250V, 3.15A) FUSE2 –...
  • Page 6: Troubleshooting Guide

    AYXP9GHR [8] TROUBLESHOOTING GUIDE 1. Self-Diagnosis Function and Display Mode To call out the content of the self-diagnosis memory, hold down the emergency operation button for more than 5 seconds when the indoor unit is not operating. • The number of indications displayed by the LEDs on the outdoor unit differs from that for the 2001 cooling unit models (for detailed display of mal- function information).
  • Page 7 AYXP9GHR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 2 times Cycle tempera- Compressor high-...
  • Page 8 AYXP9GHR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ 6 times Outdoor unit DC DC overcurrent error (1) IPM continuity check (1) Replace the outdoor...
  • Page 9 AYXP9GHR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ Outdoor unit DC Outdoor unit DC fan (1) Check connector CN3 of...
  • Page 10 AYXP9GHR Status of Indication Malfunction Content of diagnosis Inspection location/method Remedy indoor/ by LED1 No. dis- outdoor on out- played on units door unit main unit display sec- tion *1 Main Sub- Main category Sub-category cate- cate- gory gory Indoor/ Indoor unit fan Indoor unit fan error (1) Check the indoor fan...
  • Page 11 AYXP9GHR Malfunction indications due to erroneous wiring during air conditioner installation Inter-unit wiring error mode Symptom Indoor unit relay Turns On momentarily, then turns Off. Malfunction diagnosis display "18-1" Indoor Outdoor unit unit Indoor unit relay Relays turns Off after about 30 minutes. Malfunction diagnosis display None (Displays "18-0"...

This manual is also suitable for: