Table Of Contents; Introduction - Fedders C1018BBD Installation, Operation And Maintenance Manual

Model c10 & c12 series — 1.5 thru 5 ton split system high efficiency air conditioner
Table of Contents

Advertisement

TABLE OF CONTENTS

CONSUMER INFORMATION
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operation and Maintenance Instructions . . . . . . . . . . . . .3
DEALER INSTALLATION
Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Condensing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Evaporator & Condensate Drain . . . . . . . . . . . . . . . . . . .4
Suction & Liquid Lines . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Replacement Application . . . . . . . . . . . . . . . . . . . . . . . . .5
Electrical Hook-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Field Charging Procedures . . . . . . . . . . . . . . . . . . . . .6, 7
Air Handler & Evaporator Match-ups . . . . . . . . . . . . . . . .8
To Install Piston . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
CONGRATULATIONS
You have made a major investment in a fine piece of equipment. Keep
your investment sound by reading these instructions before installing
this unit. This will ensure that the full potential of this equipment is
achieved. It will also be helpful in avoiding any needless service costs
or operational problems. Included in these instructions are safety
rules, installation, operation, and maintenance instructions.
Only the highest quality components were used in the construction of
your unit. With proper maintenance, your system should provide years
of economical, trouble-free service.
SERIES NOMENCLATURE
CONDENSING UNIT
NOMENCLATURE
AIR HANDLER NOMENCLATURE
MODEL
DESIGN
SERIES
SERIES
A
24 B
NOMINAL
EVAPORATOR
BTUH
DESIGNATION
REMOTE
CONDENSER
AIR CONDITIONER
1
INSPECTION AND UNPACKING
A thorough inspection of the shipping container should be made
immediately upon receiving your unit. Look for any punctures or
openings, and if it appears damage has occurred, it should be noted
on the freight bill before signing. The delivering carrier should be
contacted immediately to inspect damage, and no installation work
should begin until this inspection is completed.
NOTES TO INSTALLER
The words "SHALL" and "MUST" indicate a requirement which is
essential to satisfactory and safe product performance. The words
"SHOULD" and "MAY" indicate a recommendation or advice which
is not essential and not required but which may be useful or helpful.
The instructions are for the use of qualified individuals specially
trained and experienced in the installation of this type of equipment
and related system components.
Installation and service personnel are required by some locales to
be licensed. Persons not qualified SHALL NOT install this
equipment nor interpret these instructions.
This installation and maintenance manual is provided to ensure the
proper installation and the most satisfactory performance of your
equipment. The instructions contained herein SHALL NOT be
deemed to extend, modify, alter or expand any of the
representations contained in the limited warranty.
WARNING:
!
DAMAGE EQUIPMENT, CAN CREATE A HAZARD, AND
WILL VOID THE WARRANTY.
DANGER:
!
THIS EQUIPMENT, POWER SUPPLY MUST BE
TURNED OFF AT THE HOUSEHOLD SERVICE BOX TO
AVOID THE POSSIBILITY OF SHOCK, INJURY, DEATH OR
DAMAGE TO EQUIPMENT.
UNIT
NOMINAL
CAPACITY
CHASSIS
EFFICIENCY
C
12
24
B
OPTION LEVEL
D = STANDARD UNIT R-22
E = STANDARD UNIT R-407
F = HIGH & LOW PRESSURE SWITCH
COIL NOMENCLATURE
E 36 12 A 68 S R 16 M1 0 X
E = Matched System Coil
I = Mixed System Coil
Nominal Capacity
Slab Code
Coil Type:
A = "A" Coil
P = Plenum Coil
Expansion Device: Two Digits = Flowrator Piston Size
E4 = Non-Bleed Type TXV 3.5 - 5 Ton
E6 = Non-Adjustable TXV, 1.5 - 3 Ton,
Matched System E-Coil
E8 = Non-Adjustable TXV, 3.5 - 5 Ton,
Matched System E-Coil
2
IMPROPER
INSTALLATION
BEFORE PERFORMING ANY WORK ON
MODEL
VERSION
BRAND
B
D
X - V
X
V = VALVE SWEAT TYPE FITTING
1 = 230/208 VOLT, 1 PHASE, 60 Hz
2 = 220/240 VOLT, 1 PHASE, 50 Hz
3 = 230/208 VOLT, 3 PHASE, 60 Hz
4 = 460 VOLT, 3 PHASE, 60 Hz
5 = 230 VOLT, 3 PHASE, 50 Hz
6 = 380 VOLT, 3 PHASE, 50 Hz
Housing Color Designation
0 = No Color; 1 = Color
i.e., M7, 72, M6, 12 (Non-Housed Coils = XX)
Drain Pan Width: 13", 15", 16", 18", 20", 21", or 23"
Manifold Position: R = Residential (Right Side)
Connection Type: K = Mobile w/Plate Kit Option
MAY
Branding Designation
Housing Designation
L = Residential (Left Side)
M = Mobile Home
S = Sweat

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C1030bbdC1024bbdC1036bbdC1042bbdC1048bbdC1060cbd ... Show all

Table of Contents