1.1.4.2.1 When running in normal status, control of compressor frequency:
Temperature difference (o
C)
Maximum frequency (Hz)
1.1.4.1.2
When running in dehumidify mode, the outdoor ambient temperature restricts frequency as follows:
(only applying to the machine models with outdoor ambient temperature sensor).
Outdoor ambient temp. (oC)
ΔT≥15
ΔT < 15
1.1.5 Defrosting running
1.1.5.1 Defrosting process
When defrosting during heating operation, frequency is not controlled according to the temperature difference, and
the maximum heating frequency is displayed.
Compressor does not stop in the process of defrosting.
Defrosting beginning conditions: Heat mode, the first power on operation or the lasting time to the previous
defrosting finishing is more than 47 minutes, and the outdoor ambient temperature is continuously found to be less
than -4oC ( model: 09) or -5oC (12) during compressor running, and then defrosting starts.
Defrosting process as following illustration:
Outdoor fan
4-way valve
Compressor
55S
1.1.5.2 Air volume control during defrosting
20 seconds Low wind is firstly selected during defrosting, then indoor fan stops running.
1.1.6 Special function
1.1.6.1 Trial running
1.1.6.1.1 Beginning conditions
Pressing emergency button 5-10 seconds and buzzer sounding twice, then starts.
1.1.6.1.2 Running status
When in trial running, the display frequency of compressor is 58Hz, running mode is cool, compressor keeps on
Domestic Air Conditioner
ΔT> 5.7
High frequency
Maximum frequency (Hz)
74 Hz
No limitation
Defrosting process
Defrosting process
5S
Defrosting process
26
5.7 ≥ΔT≥
1.3 ≥ΔT≥
1.3
-0.7
Mid. frequency
Low frequency
55S
60S
Defrosting finish
HSU-09H03/(BP)1
Model:
HSU-12H03/(BP)1
ΔT < -0.7
Compressor
stops
compressor restart