Table 6.2 System-Level Field Troubleshooting - Fujitsu MAU3147RC Product/Maintenance Manual

Hide thumbs Also See for MAU3147RC:
Table of Contents

Advertisement

Diagnostics and Maintenance
Item
DC power level
Electrical noise
Drive selection address
System cables
System diagnostic test
Intermittent or nonfatal errors
6-12
Table 6.2
System-level field troubleshooting
Check that the DC voltage is within the specified range (±5%).
For +5V DC, measure the voltage between pin P8 (+5V) of the interface
connector and the nearest PCA mounting screw (GND) from the
interface connector, and confirm the value is from 4.75 to 5.25 VDC.
For +12V DC, measure the voltage between pin P14 (+12V) of the
interface connector and the nearest PCA mounting screw (GND) from
the interface connector, and confirm the value is from 11.4 to 12.6 VDC.
Make sure the maximum ripple peak-to-peak value of +5V DC is within
250 mV and +12V DC is within 250 mV.
Make sure the high frequency noise (over 20 MHz) is less than
100 mVp-p.
Check that the disk drive selection address is set correctly.
Check that all system cables are connected correctly.
When possible, execute the system level diagnostic routine as explained
in the host computer manual. This gives a detailed report of a possible
fault.
Check the AC voltage from the power supply. Check the DC voltage
level at the power connector for the disk drive.
If the AC voltage level is abnormal or there is a lot of electrical noise,
notify the user of the error.
If the DC voltage level is unstable, replace the power supply unit.
If possible, replace the disk drive. If replacing the disk drive does not
eliminate the error, the removed disk drive is probably not faulty. To
continue error analysis, refer to the hardware and software manuals
supplied with the system.
Recommended work
C141-E222