Desa RFN28TB Owner's Operation And Installation Manual page 11

Vent-free natural gas compact fireplace
Table of Contents

Advertisement

AIR FOR
COMBUSTION
AND
VENTILATION
Continued
101934
VENTILATION AIR
(Continued)
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide
two permanent openings: one within 12" of the ceiling and one within 12" of
the floor. Connect these items directly to the outdoors or spaces open to the
outdoors. These spaces include attics and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation grills or ducts.
Do not provide openings for inlet or outlet air into attic if attic
IMPORTANT:
has a thermostat-controlled power vent. Heated air entering the attic will
activate the power vent.
Outlet
Air
Outlet
Air
Inlet
Air
Inlet Air
Figure 9 - Ventilation Air from Outdoors
Ventilated
Attic
To Attic
To
Crawl
Space
Ventilated
Crawl Space