USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
®
Owner's Manual
AQRS340
AQRS325
AQRS315
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
Contents
Before You Begin...........................2
Mounting the Equipment...............7
Plumbing......................................8
Electrical.................................,,...9
Preparing Water...........................17
Configuration..............................20
Operation....................................22
Remote Operation.......................28
Warranty......................................30
092769 RevA

Advertisement

loading

Summary of Contents for Hayward AquaRite S3 Series

  • Page 1: Table Of Contents

    Contents Before You Begin......2 Mounting the Equipment....7 Plumbing........8 Electrical.........,,...9 Preparing Water......17 Configuration......20 Operation........22 Remote Operation.......28 Warranty........30 AQRS340 AQRS325 AQRS315 Hayward Industries 400 Connell Drive, Suite 6100 Berkeley Heights, NJ 07922 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2 • Hayward salt systems are designed, tested and sold as systems and are certified by several agencies around the globe --- with each component of the systems meeting all required certi- fications and attendant legal requirements. The use of an untested, uncertified generic cells (or generic circuit boards) with Genuine Hayward salt chlorination products could lead to premature product failure.
  • Page 3: Before You Begin

    (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Hayward could void the user’s authority to oper- ate this equipment.
  • Page 4 Tools and PVC glue for installing the TurboCell and flow switch NOTE: Hayward does not recommend using the AquaRite S3 to generate bromine. NOTE: Before installing this product as part of a saline water purification system in a pool or spa us-...
  • Page 5 The functions and features described in this manual assume that the AquaRite S3 is using the lat- est firmware version available from Hayward. For the AquaRite S3, a USB port is used for firmware upgrades. The latest firmware can be found on the AquaRite S3’s product page on the Hayward website.
  • Page 6 3. Electrical Wiring (page 9) High Voltage Low voltage wiring (Smart Relay, VSP, heater, sensors, heater, flow switch and TurboCell) 4. Prepare the pool water (page 17) General Water Chemistry Salt 5. System Startup (page 19) Configuration Operation USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 7 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 8: Mounting The Equipment

    When selecting a mounting location, note that the standard cables supplied with the included flow switch and TurboCell, as well as optional accessories like Hayward temperature sensors, are all 15 ft. (5m) long. Try to mount the AquaRite S3 at a height/location where the screen and keypad can be easily used.
  • Page 9: Plumbing

    #3 above to allow chlorination of both the pool and spa during spillover but preventing overchlorination when operating the spa only. Turbo Turbo Flow Cell Cell Switch Valve Valve 12” 12” Pool Pool Flow Switch Valve Valve Turbo Turbo Cell Cell Flow Switch Pool Pool USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 10: Electrical

    Use copper conductors only • Always remove power to the AquaRite S3 before removing the front panel Inside View Low Voltage Wiring High Voltage knockouts Channel Bottom View Low Voltage Wiring High Voltage knockouts Channel USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 11 For Canadian installations, the AquaRite S3 shall be connected to a circuit protected by a class A ground fault interrupter. Ground for 115 VAC use black (L1) and gray (N) for 230 VAC use black (L1) and gray (L2) USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 12 115 VAC Smart Relay Electrical Panel Powering AquaRite S3 and Smart Relay with 230 VAC 230 VAC Single Speed Pump Line 2 in Line 1 out Line 1 in Line 2 out 230 VAC Smart Relay USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 13 If the AquaRite S3 is controlling a VSP Use this wiring method when the AquaRite S3 is controlling a Hayward VSP. For Pentair VSPs, a Hayward HLPMPCONV converter (sold separately) must be used. The pump and the AquaRite S3 are continuously powered as shown. The AquaRite S3 will control the pump’s function using the low voltage communication wiring.
  • Page 14 Smart Relay Connection Hayward Variable Speed Pump (VSP) Wiring The Hayward TriStar 950, TriStar 900, Super Pump 700 and MaxFlo 500 pumps wire directly to the RS-485 connector and will be fully controlled by the AquaRite S3 (schedules and speeds). Refer to the VSP Communication Wiring table and diagrams on the following page for VSP communication wiring instructions.
  • Page 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 16 The AquaRite S3 utilizes Hayward 10K ohm thermistor type sensors for measurement of pool and air temperature. The sensors come with a 15 ft cable. If a longer cable is required, contact the Hayward Technical support for information on suitable cable types and splices.
  • Page 17 4. Ensure that the connector latch “snaps” into place. TurboCell The TurboCell should be plugged in AFTER the AquaRite S3 cover panel is installed. Refer to page 4 for the location of the chlorinator cell connector. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 18 Use the table above to determine Ti, Ci, Ai, and TDS in the formula shown above. If the Si is equal to 0.2 or more, stains may appear. If the Si is equal to -0.2 or less, corrosion or deterioration may occur. -0.2 Corrosion Stain USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 19 Always check stabilizer (cyanuric acid), when checking salt. These levels will most likely decline together. Use the chart on the following page to determine how much stabilizer must be added to raise the level to 40 ppm. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 20 Pool/spa chemicals are within the recommended levels according to the table on page 17. Pool/spa salt level is between 1200 PPM - 8000 PPM. All wiring is performed according to NEC and local codes. The AquaRite S3 is properly grounded. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 21: Configuration

    Salinity Units - Salt can be displayed in Parts Per Million (ppm) or Grams Per Liter (g/l). Make the desired selection. After making all the selections on this screen, press the “OK” button to advance to the next screen. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 22: Operation

    Also, if you have experienced problems, Hayward Technical Support may advise you to upgrade your AquaRite S3 firmware. To upgrade the AquaRite S3 firmware, prepare a FAT32 formatted USB thumbdrive. Make sure there are no files or folders on the drive.
  • Page 23 From the Home Screen, use the “+” and “-” buttons to adjust the desired chlorine level between 0% to 100% Heater Temperature Setting From the Home Screen, use the “UP” and “DOWN” buttons to adjust the desired heater setpoint from 34º to 104º. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 24 Temperature at TurboCell Chlorine Output greater than 140ºF Shut off 60ºF - 140ºF Desired Level % 50ºF - 59ºF 20% or Desired Level %, whichever is lower less than 50ºF Shut off USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 25 Freeze prot (requires Air Temperature Sensor) Use the “+” and “-” buttons to enable or disable the freeze protec- tion. Enabling recirculation freeze protection will automatically turn the pump on when the air temperature drops below the “Freeze USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 26 Press “OK” to save the selection. The is the minimum speed the pump will run while the heater is in use. This setting is useful to ensure that the heater receives a sufficient flow rate to operate regardless of schedule. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 27 Speed (only shown for VSPs) You can set a desired pump speed while the cover is closed. Use the “+” and “-” buttons to cycle through the available speeds, Low, Medium, High and Any. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 28 The System info menu allows you to view current firmware versions. Newer firmware may be avail- able from Hayward and if so, we encourage you to upgrade. Refer to the AquaRite S3’s product page on the Hayward website for the latest firmware.
  • Page 29 Press “OK” to apply the new speed setting. System config - Enable/disable or change the following configuration items: • Remote - Set mode to Master (default) or Remote (controlled by an Hayward Omni automation control). See “Remote Operation” below for more information. •...
  • Page 30: Remote Operation

    The AquaRite S3 can be configured to operate as a standalone chlorinator that is controlled by a Hayward Omni automation control or another AquaRite S3. In this configuration, the AquaRite S3 can only make chlorine and will have no other function. Chlorination settings and operation are managed by the Omni automation control or the Master AquaRite S3.
  • Page 31 With either configuration, the remote AquaRite S3 must have a connected flow switch and will not produce chlorine unless there is adequate flow. An AquaRite S3 in Master mode can also control a Hayward AquaRite AQR chlorinator using an HLAQRPCB communication board. Wire the RS-485 from the Master AquaRite S3 to the RS-485 on the communication board in the same manner as the diagrams on the previous page.
  • Page 32: Warranty

    AquaRite, AquaRite Pro, AquaPlus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Hayward also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year.