Air to Water Heat Pump (Split integrated DHW type)
Packing list
Heat pump (HP)
Model
Waterstage High Power Integrated DHW 11 Single phase
Waterstage High Power Integrated DHW 14 Single phase
Waterstage High Power Integrated DHW 11 3-Phase
Waterstage High Power Integrated DHW 14 3-Phase
Waterstage High Power Integrated DHW 16 3-Phase
Optional equipment
• 2nd circuit kit (code UTW-KZDXE)
for connecting 2 heating circuits.
• Regulation extension kit (code UTW-KREXD)
to manage a 2nd heating circuit, swimming pool,
telephone modem etc...
• Boiler connection kit (code UTW-KBDXD)
for connecting a boiler to the heat pump.
• Room thermostat (code UTW-C55XA),
Wireless room thermostat (code UTW-C58XD)
for correcting the ambient temperature.
• Remote control (code UTW-C74XF or
UTW-C74HXF),
Wireless remote control (code UTW-C78XD)
for correcting the ambient temperature and
programming the heat pump.
• Swimming pool kit (code UTW-KSPXE).
• Cooling kit (code UTW-KCLXD).

1 Description of the unit

1 .1

Package

• 1 package: Outdoor unit.
• 1 package: Hydraulic unit and outdoor sensor.
- 4 -
Outdoor unit
Model
WOYG112LHT
WOYG112LCTA
WOYG140LCTA
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
Scope of application
This heat pump provides:
- Heating in winter,
- Control of two heating circuits*,
- Production of domestic hot water.
- Installation
with
boiler
supplementary
heating
or
- The addition of electrical back-ups*, for extra heating
on the coldest days.
- Cooling in summer* (for floor heating-cooling system
or fan-convectors).
- Heating the swimming pool*.
: These options require the use of additional kits
*
(see chapter "Optional equipment").
1 .2

Definitions

- Split: The heat pump consists of two elements
(an outdoor unit for outdoor and a hydraulic unit for
inside the dwelling).
- Air/water: The surrounding air is the energy source.
This energy is transmitted to the water in the heating
circuit by the heat pump.
- Inverter: the fan and compressor speeds are modulated
according to the heating requirements. This technology
enables you to save on energy and operate on a single-
phase power supply, whatever the heat pump's output,
by avoiding heavy intensities on start-up.
- COP (coefficient of performance): this is the relationship
between the energy transmitted to the heating circuit
and consumed electrical energy.
Installation and operating manual "1768 - EN"
Hydraulic unit
Model
WGYG140DG6
WGYK160DG9
connection*
as
for
the
coldest
days.
a

Hide quick links: