Indoor/Outdoor Unit Installion Drawings - Haier 1U09MACFRA Installation Manual

Table of Contents

Advertisement

Indoor/Outdoor Unit Installation Drawings
The models adopt HFC free refrigerant R32.
For installation of the indoor units,refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)
more than 20cm
more than
10cm
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
The marks from
to
A
in the gure are the
G
parts numbers.
The indoor unit should
be installed at the
recommended
height(2m).
more than 60cm
1.When installing the unit to wall, roof or rooftop, fix a supporter
surely with nails or wires in preparation of earthquake and strong wind.
2.Air conditioner mounted not above and one meter away from electric
equipment such as television.
Please be subjected to the actual product purchased.
more than 60cm
more than 10cm
4
Compressor(Inside of Unit)
Attention must be paid to
the rising up of drain hose
G
more than 10cm
A
more than
10cm
D
more than 30cm
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
F
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
C
F
Heating insulating material
Piping hole cover
G
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
When tting the unit to wall
surface, roof or rooftop, x
a supporter surely with nails
or wires in consideration of
E
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.
12