Indoor/Outdoor Unit Installion Drawings - Haier 1U09MADFRA Installation Manual

Hide thumbs Also See for 1U09MADFRA:
Table of Contents

Advertisement

Indoor/Outdoor Unit Installation Drawings
The models adopt HFC free refrigerant R32.
For installation of the indoor units,refer to the installation manual which was provided with the
units.(The diagram shows a wall-mounted indoor unit.)
more than 20cm
more than
10cm
Arrangement of piping
directions
Rear left
Left
Below
The marks from
to
A
in the figure are the
B
parts numbers.
The indoor unit should
be installed at the
recommended
height(1.8m).
more than 60cm
1.When installing the unit to wall, roof or rooftop, fix a supporter
surely with nails or wires in preparation of earthquake and strong wind.
2.Air conditioner mounted not above and one meter away from electric
equipment such as television.
Please be subjected to the actual product purchased.
Rear
right
Right
more than 60cm
more than 10cm
Compressor(Inside of Unit)
Attention must be paid to
the rising up of drain hose
more than 10cm
A
more than
10cm
more than 30cm
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
B
Optional parts for piping
Non-adhesive tape
A
Piping hole cover
B
F
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
C
Heating insulating material
F
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts
firmly and horizontally.
When fitting the unit to wall
surface, roof or roofto
D
a supporter surely with nails or
wires in consideration of
E
earthquake and strong wind.
If vibration may affect the
house,
fix
vibration-proof mat.
p,fix
the unit by attaching a
12