INSTALLATION TYPES

2
This oven is designed for adaptation to the following three
types of ventilation:
A. Outside Top Exhaust (Vertical Duct)
B. Outside Back Exhaust (Horizontal Duct)
C. Recirculating (Non-Vented Ductless)
OUTSIDE TOP EXHAUST
A
(VERTICAL DUCT)
See page 12
Installation Instructions
(Choose A, B or C)
RECIRCULATING
C
(NON-VENTED DUCTLESS)
See page 19
NOTE: This oven is shipped assembled for Outside Top
Exhaust (except for non-vented models). Select the type
of ventilation required for your installation and proceed
to that section.
OUTSIDE BACK EXHAUST
B
(HORIZONTAL DUCT)
See page 15
11
On models shipped for
non-vented exhaust, a
disposable charcoal filter is
included with the oven and
needs to be installed to help
remove smoke and odors.
On models shipped for outside
top exhaust, a Charcoal Filter
Accessory Kit is required for
the non-vented exhaust. (See
your Owner's Manual for the kit
number.)