Anomaly
Type of
anomaly
N°452
Stops
machine.
Fd02
N°453
Stops
machine.
Fd03
N°454
Stops
machine.
Fd04
N°455
Stops
machine.
Fd05
N°456
Stops
machine
Fd06
N°457
Stops
machine.
Fd07
N°458
Stops
machine.
Fd08
N°459
Stops
machine.
Fd09
N°460
Stops
machine
Fd10
92
Description
Possible
causes
Lower motor
- Wrong motor
speed
parameter.
inconsistency.
- Phase not
connected.
- Excessive fric-
tion (see FU01).
Lower Inverter
- Internal issue
Under Voltage
with the inverter
DC.
hardware.
Lower Inverter
External power
Over Voltage
supply
fluctuation.
-Internal issue
with the inverter
hardware.
Lower Inverter
Defective /
outgoing
unplugged con-
phases open
nector on
circuit.
inverter.
Upper Inverter
Wrong motor
outgoing
parameter. Gen-
phases open
eral overheating
circuit.
of inner
components.
Upper motor
All causes
thermal safety
related to friction
tripping (Klixon).
phenomena:
- Cavity fan
towards suction
wall.
- Motor shaft
towards graph-
itic ring.
- Cleaning cycle
with excessive
water load.
Upper motor
All causes
thermal safety
related to friction
tripping (Klixon).
phenomena:
- Cavity fan
towards suction
wall.
- Motor shaft
towards graph-
itic ring.
Lower Inverter
Inverter hard-
Drive Interlock
ware issue.l
failure.
Upper Inverter
Inverter hard-
Drive Interlock
ware/harness
failure
issue.
Instructions to User
Restart oven.
If the causes persist,
error will appear again,
call Service.
Restart oven.
If the causes persist,
error will appear again,
call Service
Check the power supply
is stable (check function-
ality of other units nearby
the oven.
Restart oven, If the
causes persist, error will
appear again, call
service.
Call Service.
Clean air inlet filter, let he
unit to cool down. Restart
oven. If the causes per-
sist, error will appear
again.
Call service
If in cooking phase: wait
for the motor to cool
down and restart the
oven after 30 min. If the
problem persists call
Service.
If in cleaning phase: call
Service.
Restart oven. If the
causes persist, error will
appear again, call
Service.
Call Service.
Call Service.
Action for Service*
Check parameter 198
consistency
Ensure all phases are correctly
connected
Refer to Service Actions as for
the FU01 (see "Inverter (MD/
motor drive" section in "Detailed
appliance and components
description/functioning" chapter
of the proper Service manual).
Restart oven, If the causes per-
sist, error will appear again.
Replace inverter (see "Inverter"
section in "Servicing the appli-
ance" chapter of the proper
Service manual).
Check the power supply is stable
(check functionality of other units
nearby the oven.
Restart oven, If the causes per-
sist, error will appear again.
Replace inverter (see "Inverter"
section in "Servicing the appli-
ance" chapter of the proper
Service manual).
Check inverter connector and
ensure outgoing phases are prop-
erly plugged.
Detection mode: T>100℃ on
Inverter sensor
- Check parameter 198
consistency.
- Clean air inlet filter.
- Check for motor fan frictions
(refer to Service actions as for the
FU01).
The self resetting Klixon opens at
130℃
Check for motor fan frictions
(refer to Service actions as for the
FU01)
Restart oven, if the problem per-
sist replace motor.
If the error was detected during a
cleaning cycle, troubleshoot the
water loading circuit. Especially
check the flowmeter cleanness
Ensure the cavity fan does not
interfere with suction wall. In case
fix the interference by ensuring
the proper positioning of the suc-
tion wall.
Replace graphitic rings and clean
the motor shaft prior to reassem-
ble (see "Inverter (MD/motor
drive" section in "Detailed appli-
ance and components
description/functioning" chapter
of the proper Service manual).
Replace inverter (see "Inverter"
section in "Servicing the appli-
ance" chapter of the proper
Service manual).
Replace inverter (see "Inverter"
section in "Servicing the appli-
ance" chapter of the proper
Service manual).