Emerson Dixell XB Series Installing And Operating Instructions page 5

Blast chiller
Table of Contents

Advertisement

HOW DISPLAY / MODIFY THE SET
POINT OF THE HOLDING PHASE
-
TO
DISPLAY:
release the SET key (6), the
holding
set
selected cycle is displayed for
5 sec.
-
TO MODIFY: while the set
point is displayed hold pushed
the SET key till the HdS label
start flashing. Use the UP and
DOWN key to modifiy the
value..
TO CONFIRM: push the SET key to
confirm the value and exit.
HOW MODIFY A CYCLE:
1. Push the
key (6) for several
seconds till the first parameter (CyS)
is displayed.
2. Use the UP and DOWN keys to
browse the parameters.
3. To modify a parameter push the SET
key and use the arrow keys.
4. Confirm the new value by pushing the
SET key.
5. The new value is recorded even if the
programming is exited by time out.
8.3 KEYBOARD WHEN A CYCLE 1,2,3,4 IS RUNNING
DISPLAY TEMPERATURES:
The
upper
display
temperature of the thermostat probe
The
bottom
display
temperature of a insert probe (if
enabled) or the count down timer.
By pushing DOWN key, the probes
iP1, iP2, iP3 and the count-down timer
are displayed in sequence.
1592006207 XB570L GB r1.1 23.03.2015
push
and
point
of
the
shows
the
shows
the
XB570L
In
this
example
the
holding set point of the
cycle 1 is modified.
In this example
the set point of
the holding
cycle is
modified.
3/20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dixell xb570lDixell xb570l-5r0c1-x378254

Table of Contents