11. Electrical characteristics

Model name
Voltage
Power supply
Frequency
Maximum operating current *
Starting current
Main fuse (Circuit breaker) current
Power cable
2
Wiring spec. *
Connection
cable *
1
*
: Maximum operating current is the total current of the indoor unit and the outdoor unit.
2
*
: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
3
*
: This is the wiring length in case voltage descent is less than 2%. When the wiring length be-
comes longer, select the wiring of a more larger diameter.
1
Cross-sectional area
3
Limited wiring length
AOYG14KBTA2
V
Hz
A
10.9
A
4.7
A
2
mm
m
- 287 -
AOYG18KBTA2
230 ~
50
11.6
5.6
15
1.5
1.5
21