Terminations/Spark Arrestor
The fireplace system must be terminated with the listed round top or
chase terminations. In any case, refer to the installation instructions
supplied with the termination.
CAUTION: Do not seal openings on the rooftop
flashing. Follow the installation instructions provided
with the termination being used.
Stainless Inner
Flue Pipe
Secure Termination
to Outer Pipe with 3
Screws
Overlap Shingles (Top and
Sides of Flashing Base)
Figure 18 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with the chase style
termination chosen. In a multiple chase installation, be sure to provide
adequate distance between terminations to prevent smoke spillage
from one termination to another. We suggest that terminations be
separated at least 24", center to center and stacked at a vertical height
difference of 18" (see Figure 19).
Note: If a decorative shroud is to be installed, contact the manufac-
turer for specifications.
24" (610 mm)
24" (610 mm)
Figure 19 - Multiple Chase Installation
126595-01_J
VENTING INSTALLATION Continued
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of
3 feet in height above the highest point where it passes through the
roof and must be at least 2 feet above the highest point of the roof
that is within a horizontal distance of 10 feet (see Figure 20).
RLT-12D
Level of Flue
Gas Outlet
Waterproof
Caulking
Storm
Collar
Flashing
SQUARE TOP TERMINATIONS INSTALLATION STL-12D AND
STL-12DMP
Underlap Shingles
1.
2.
(762 mm)
Min.
18" (458 mm)
Min. Typ.
SuperiorFireplaces.us.com
10'
(3.05 m)
3'
2' (0.61 m) Min.
(0.91 m)
Min
Figure 20 - 10 Foot Rule
Construct chase as illustrated in Figure 21. Note: The shortest
vertical side must be at least 30" high and minimum inside di-
mension must be at least 19" as shown in Figure 21.
Add pipe sections to chimney system as outlined in fireplace
installation instructions until last piece of chimney is a maximum
of 6" below top of chase (see Figure 21).
(483 mm)
30"
Figure 21 - Constructing Chase
Level of Flue
Gas Outlet
10'
(3.05 m)
2' (0.61 m)
Min.
(0.91 m)
Min
19"
6" (153 mm) Max.
3'