Carrier 42TVBA010 Installation Manual
Hide thumbs Also See for 42TVBA010:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

INSTALLATION MANUAL
AIR CONDITIONER (SPLIT TYPE)
Indoor unit
42TVBA010, 013, 016
Outdoor unit
38TVBA010, 013, 016
R32
ENGLISH
ภาษาไทย
1 1 22 3 50 1 16

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 42TVBA010

  • Page 1 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) ภาษาไทย Indoor unit 42TVBA010, 013, 016 Outdoor unit 38TVBA010, 013, 016 1 1 22 3 50 1 16...
  • Page 2: Table Of Contents

    สารบั ญ CONTENTS ข อ ควรระวั ง เพ อความปลอดภั ย ............. PRECAUTIONS FOR SAFETY ..........1 ชิ ้ น ส ว นอุ ป กรณ เ สริ ม ..............ACCESSORY PARTS ............5 ผั ง การติ ด ตั ้ ง ตั ว เคร องภายในและภายนอก ........INSTALLATION DIAGRAM OF INDOOR AND ชิ...
  • Page 3: Precautions For Safety

    PRECAUTIONS FOR SAFETY PRECAUTIONS FOR SAFETY Read the precautions in this manual carefully before This appliance is fi lled with R32. operating the unit. • Before installation, please read these precautions for safety carefully. • Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.
  • Page 4 • TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC. • WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R32) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE.
  • Page 5 • Thickness of copper pipes used R32 must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm. • Do not perform fl are connection inside a building or dwelling or room, when joining the heat exchanger of indoor unit with interconnection piping. Refrigerant connection inside a building or dwelling or room must be made by brazing or welding.
  • Page 6 REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.
  • Page 7: Accessory Parts

    ACCESSORY PARTS ACCESSORY PARTS Indoor Unit Part name Part name Installation plate × 1 Wireless remote control × 1 Battery × 2 Remote control holder × 1 Ultra pure fi lter × 2 Mounting screw × 6 Flat head wood screw × 2 Owner’s Manual ×...
  • Page 8: Installation Diagram Of Indoor And Outdoor Units

    28 mm Air inlet Liquid side : Ø6.35 mm 500 mm Gas side : Ø9.52 mm Air inlet 97 mm (42TVBA010, 013) each : Ø12.70 mm (42TVBA016) Pipe insulating material Air outlet 90 mm (polyethylene foam, 6 mm thick) 600 mm...
  • Page 9: Indoor Unit

    INDOOR UNIT INDOOR UNIT When the installation plate is directly mounted Installation Place on the wall • A place which provides the spaces around the indoor unit as shown in the 1. Securely fi t the installation plate onto the wall by screwing it in the upper diagram and lower parts to hook up the indoor unit.
  • Page 10: Piping And Drain Hose Installation

    Front panel Control wire Control wire Screw (Ø3.1×16L) for hang remote controller Hole for hang remote controller Remote controller Wall Screw Screw Remote controller Screw (Ø3.1×25L) for fi x battery cover Screw cap * Wire size 28-22AWG 70 mm or 0.08-0.32 mm Outer diameter not over 4.7 mm, control wire length 30 m.
  • Page 11: Indoor Unit Fixing

    How to remove the drain hose NOTE • The drain hose can be removed by removing the If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. screw securing the drain hose and then pulling out After passing the connecting pipe through the pipe hole, connect the the drain hose.
  • Page 12: Outdoor Unit

    2. Put water in the drain pan and make sure that the water is drained out of CAUTION doors. 3. When connecting extension drain hose, insulate the connecting part of Arrange the drain pipe for proper drainage from the unit. extension drain hose with shield pipe.
  • Page 13: Evacuating

    (Unit : N·m) CAUTION Outer dia. of copper pipe Tightening torque • KEEP IMPORTANT 6 POINTS FOR PIPING WORK. Ø6.35 mm 16 to 18 (1.6 to 1.8 kgf·m) (1) Take away dust and moisture (inside of the connecting pipes). Ø9.52 mm 30 to 42 (3.0 to 4.2 kgf·m) (2) Tighten the connections (between pipes and unit).
  • Page 14: Electrical Works

    ELECTRICAL WORKS ELECTRICAL WORKS Model 42TVBA010 42TVBA013 42TVBA016 Power source 50Hz, 220 V Single phase Maximum running current 5.30A 6.30A 8.70A Circuit breaker rating Power supply cable H07RN-F or 60245 IEC66 (1.25 mm or more) Connecting cable H07RN-F or 60245 IEC66 (0.75 mm...
  • Page 15: Power Supply And Connecting Cable Connection

    Power Supply and Connecting Cable Connection Power Supply Input at Outdoor Unit Terminal Block Indoor Unit Outdoor Unit Connecting cable Connecting cable connect to 1 2 3 Terminal block Terminal block (1 2 3) Connecting cable Power cord Earth line Earth line Earth line Connecting cable...
  • Page 16: Others

    OTHERS OTHERS Gas Leak Test Test Operation To switch the TEST RUN (COOL) mode, press [RESET] button for Check places for 10 seconds. (The beeper will make a short beep.) the indoor unit. OPERATION / RESET Button Check places for the outdoor unit.
  • Page 18: ข อ ควรระวั ง เพอความปลอดภั ย

    ข อ ควรระวั ง เพอความปลอดภั ย ข อ ควรระวั ง เพอความปลอดภั ย อ า นข อ ควรระวั ง ในคู  ม ื อ นี ้ อุ ป กรณ น ี ้ ต  อ งเติ ม ด ว ยสารทํ า ความเย็...
  • Page 19 เพอเป น การป อ งกั น ตั ว เครองภายในไม ใ ห ร  อ นเกิ น และไม ท ํ า ให เ กิ ด อั น ตรายจาก • เพลิ ง ไหม ว างเครองให ห  า ง (มากกว า 2 ม.) จากแหล ง ความร อ น เช น เครองกระจาย ความร...
  • Page 20 ความหนาของท อ ทองแดงที ่ ใ ช R32 จะต อ งมากกว า 0.8 มม. ห า มใช ท  อ ทองแดงที ่ ห นา • น อ ยกว า 0.8 มม. โดยเด็ ด ขาด อย า ทํ า การท อ ต อ แบบปลายบานภายในอาคาร ที ่ พ ั ก อาศั ย หรื อ ห อ งพั ก เมอต อ เครองแลก •...
  • Page 21 ข อ กํ า หนดในการแจ ง การไฟฟ า ส ว นท อ งถิ ่ น โปรดตรวจสอบให แ น ใ จว า ได แ จ ง การไฟฟ า ส ว นท อ งถิ ่ น ให ท ราบถึ ง การติ ด ตั ้ ง เครื ่ อ งนี ้ ก  อ น ดํ...
  • Page 22: ชิ ้ น ส ว นอุ ป กรณ เ สริ ม

    ชิ ้ น ส ว นอุ ป กรณ เ สริ ม ชิ ้ น ส ว นอุ ป กรณ เ สริ ม ตั ว เคร องภายใน หมายเลข ช อชิ ้ น ส ว น หมายเลข ช อชิ ้ น ส ว น แผ...
  • Page 23: ผั ง การติ ด ตั ้ ง ตั ว เครองภายในและภายนอก

    ด า นก า ซ 9.52 มม. Ø อย า งละชิ ้ น ช อ งระบาย มม. อากาศ (42TVBA010, 013) 12.70 มม. Ø (42TVBA016) ช อ งระบายอากาศ วั ส ดุ ท ี ่ ใ ช เ ป น ฉนวนท อ มม.
  • Page 24: ตั ว เครองภายใน

    ตั ว เครองภายใน ตั ว เครองภายใน เม อติ ด แผ น ติ ด ตั ้ ง กั บ ผนั ง โดยตรง สถานที ่ ต ิ ด ตั ้ ง 1. ติ ด แผ น ติ ด ตั ้ ง เข า กั บ ผนั ง โดยใช ส กรู ย ึ ด ที ่ ส  ว นบนและส ว นล า งเพ อเกี ่ ย วเข า กั บ สถานที...
  • Page 25: การติ ด ตั ้ ง ท อ น้ ํ า ทิ ้ ง และท อ ส ง

    แผงด า นหน า สายควบคุ ม สกรู ( 16L) สายควบคุ ม Ø × สํ า หรั บ แขวน รี โ มทคอลโทรล รู ส ํ า หรั บ แขวน รี โ มทคอนโทรล รี โ มทคอนโทรล ผนั ง สกรู สกรู รี โ มทคอนโทรล สกรู...
  • Page 26: การติ ด ตั ว เคร องภายใน

    วิ ธ ี ก ารถอดท อ น้ ํ า ทิ ้ ง หมายเหตุ สามารถถอดท อ น้ ํ า ทิ ้ ง ออกได โ ดยถอดสกรู ท ี ่ ย ึ ด ท อ น้ ํ า ทิ ้ ง • ถ า ดั ด ท อ ไม ถ ู ก ต อ ง อาจทํ า ให ต ั ว เคร องภายในติ ด บนผนั ง ไม ม ั ่ น คง หลั ง สอดท อ ต อ จากนั...
  • Page 27: ตั ว เครองภายนอก

    2. ทดลองใส น ้ ํ า ในถาดรั บ น้ ํ า ทิ ้ ง เพ อทดสอบการระบายของน้ ํ า ออกสู  ภ ายนอก ข อ ควรระวั ง 3. เม อต อ ท อ ต อ น้ ํ า ทิ ้ ง หุ  ม ส ว นเช อมต อ ท อ ต อ น้ ํ า ทิ ้ ง ด ว ยฉนวนหุ  ม ท อ จั...
  • Page 28: การไล อ ากาศออก

    (หนวย : นิ ว ตั น เมตร) ข อ ควรระวั ง เส น ผ า ศู น ย ก ลางภายนอกของท อ ทองแดง แรงบิ ด ในการขั น แนน 6 จุ ด สํ า คั ญ ในการเดิ น ท อ • 6.35 มม. 16 ถึ...
  • Page 29: การทํ า งานเกี ่ ย วกั บ ไฟฟ า

    การทํ า งานเกี ่ ย วกั บ ไฟฟ า การทํ า งานเกี ่ ย วกั บ ไฟฟ า รุ  น 42TVBA010 42TVBA013 42TVBA016 แหล ง จ า ยไฟฟ า 50Hz, 220 V 1 เฟส กระแสไฟฟ า สู ง สุ ด...
  • Page 30: แหล ง จ า ยไฟและการเช อมต อ สายเช อมต อ

    แหล ง จ า ยไฟและการเช อมต อ สายเช อมต อ กํ า ลั ง กระแสไฟฟ า ของแหล ง จ า ยไฟที ่ บ ล็ อ คขั ้ ว ต อ ของตั ว เคร องภายนอก ตั ว เครื ่ อ งภายใน ตั...
  • Page 31: ระบบอน ๆ

    ระบบอน ๆ ระบบอน ๆ การทดสอบการรั ่ ว ของสารทํ า ความเย็ น การทดสอบ เพ อสลั บ ไปยั ง โหมด TEST RUN (COOL) กดปุ  ม [RESET] ค า งไว น าน จุ ด ตรวจสอบ 10 วิ น าที (จะเกิ ด เสี ย งป  บ สั ้ น ๆ) ตั...
  • Page 33 MEMO...
  • Page 34 MEMO...
  • Page 36 1122350116...

This manual is also suitable for:

42tvba01342tvba01638tvba01038tvba01338tvba016

Table of Contents