Condensate Drain Connection; Horizontal Left Configuration - International comfort products F96VTN Installation Instructions Manual

Two-stage, variable speed, 35” tall high efficiency condensing gas furnace
Table of Contents

Advertisement

Fig. 10 - - Downflow Trap Configuration
(Appearance may vary)
Fig. 11 - - Horizontal Right Trap Configuration
(Appearance may vary)
440 01 4800 01
A11587

CONDENSATE DRAIN CONNECTION

FROZEN AND BURST WATER PIPE HAZARD
Failure to protect against the risk of freezing may result in
property damage.
Special precautions MUST be made if installing furnace in an
area which may drop below freezing. This can cause improper
operation or damage to equipment. If furnace environment
has the potential of freezing, the drain trap and drain line must
be protected. The use of accessory drain trap heaters, electric
heat tape and/or RV antifreeze is required for these
installations.
PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in burst water pipes
A11573
and/or property damage.
If a condensate pump is installed, a plugged condensate drain
or a failed pump may cause the furnace to shut down. Do not
leave the home unattended during freezing weather without
turning off water supply and draining water pipes or otherwise
protecting against the risk of frozen pipes.
Specifications subject to change without notice.
Fig. 12 - - Horizontal Left Configuration
(Appearance may vary)
CAUTION
!
CAUTION
!
A11574
13