Fujitsu ABYG18KRTA Service Manual page 162

Ceiling type air conditioner
Hide thumbs Also See for ABYG18KRTA:
Table of Contents

Advertisement

 Model: AOYG24KBTB
Fan speed is defined by outdoor temperature and compressor frequency.
• Outside air temperature zone selection
Cooling
Fan step
Y zone
S-HIGH2
S-HIGH1
1,000
HIGH
1,000
10
9
8
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,100 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
-8°C
Heating
Y zone
1,100
1,100
1,100
1,100
940
940
940
940
770
700
630
550
470
470
470
440
320
440
320
440
320
440
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
H zone
Dry
Cooling or dry at low outdoor temp.
Z zone
F zone
940
770
940
630
770
470
630
270
470
270
470
270
320
270
320
270
320
270
- (04-20) -
19°C
10°C
0°C
-10°C
Unit: rpm
G zone
320
320
320
320
270
270
220
220
220
220
220
220
220
220
220
220
220
220
H zone
270
270
190
190
190
190
190
190
190
3. Fan control