Return Air Connections
WARNING
!
FIRE HAZARD
Failure to follow this warning could cause personal
injury, death and/or property damage.
Never connect return−air ducts to the back of the
furnace. Refer to the following instructions.
441 01 1421 01
Figure 16 − Horizontal Suspension with Straps
Figure 17 − Typical Attic Installation
GAS
ENTR Y
"
3
(451mm)
17
/
4
SHEET
MET AL
22 "
UNION
Specifications are subject to change without notice.
METHOD 1
FOLD ALL STRAPS UNDER
FURNACE AND SECURE WTH
(4) #8 x 3/4 (19 mm) SHEET METAL SCREWS
(2 SCREWS IN SIDE AND 2 SCREWS
IN BOTTOM).
17
3
4
1 " (25mm) UNDER FURNACE
TYPE-B
EXTEND OUT 12 " (305mm)
VENT
FR OM FA CE OF DOOR
m m )
( 1 5 2
I N *
6 " M
30-IN . (762mm)
MIN WORK AREA
Downflow Furnaces
The return−air duct must be connected to return−air opening
(bottom inlet) as shown in Figure 21. DO NOT cut into casing
sides (left or right). Side opening is permitted for only upflow
and most horizontal furnaces. (See Figure 21) Bypass
humidifier connections should be made at ductwork or coil
casing sides exterior to furnace.
Upflow and Horizontal Furnaces
The return−air duct must be connected to bottom, sides (left
or right), or a combination of bottom and side(s) of main
METHOD 2
USE (4) #8 x 3/4 (19 mm) SHEET
METAL SCREWS FOR EACH
STRAP. THE STRAPS
SHOULD BE VERTICAL
AGAINST THE FURNACE
SIDES AND NOT PULL AWAY
FROM THE FURNACE
SIDES.
" (451mm)OVERALL
3
/
4
" (121mm) UNDER DOOR
/
4
* WHEN USED W ITH
SINGLE W ALL VEN T
CONNECTIONS
A10131
A10164
15