Operational Specification
3.1.7.1 Power supply
Item
Input Voltage range
Input Current range
Power Consumption
DPMS
Inrush Current
Earth Leakage Current
Hi-Pot
Power Line Transient
LED backlight operation
range
Power cord
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
Yes
Condition
Universal input full
range
90 ~ 264VAC
Normal "On" operation < =26 W
DPMS "Off" state
DPMS "Sleep" state
110 VAC
220 VAC
264 VAC/50Hz
1. 1500VAC, 1 sec
2. Ground test: 30A,
1sec
IEC1000-4-4
IEC1000-4-5 (Surge)
90 ~ 264VAC
- 6 -
Spec
90~264VAC /47~63Hz 
< 1.0 Arms
< 0.3 W
< 0.3 W
< 30 A (peak)
< 60 A (peak)
< 3.5 mA
Without damage
< 0.1 ohm
1KV
Common: 2KV,
Differential: 1KV
70mA Typ.
Color: Black
Length: 1800 +/- 50
mm
17 languages
6 buttons including 1
monitor power on/off
control button.
"I-Key" function
DDC2B
DDC-CI
Only for GL2055M
Only for GL2055M
Only for GL2055M
From -5 to +15 degree
OK N.A Remark
LED: Green
LED: Off
LED: Amber
Cold-start
(on-line test)
(in-lab test)
Depends on panel
source