Aiphone LEF Series Installation & Operation Manual page 11

Open voice selective call intercom
Hide thumbs Also See for LEF Series:
Table of Contents

Advertisement

3 LEF-10S, 5 Indoor Subs, 2 Door Stations with BG-10C for Chime & All Call
LE-D or
LE-D or
LE-DA
LE-DA
1
1
E
E
3 LEF-10, 6 3-call Subs, and 1 Door Station with External Signaling and Door Release
LE-D or
LE-DA
1
E
PS12
+
To Strike
Black (2)
Yellow (2)
RY-PA
&
PT
LEF-10S #1
LEF-10S #2
BG-10C
1
C
1
2
2
C
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
DB
9
9
DA
10
10
11
1
2
E
E
E
R
R
R
Y
Y
Y
+
+
+
L
L
P1
P1
P1
P2
P2
P2
P3
P3
P3
PS12
DC IN
+
+
LEF-10 #1
LEF-10 #2
LEF-10 #3
C
1
2
C
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
1
2
E
E
R
R
Y
Y
+
+
L
L
K10
K10
LEF-10S #3
LE-A or
LE-AN
1
2
C
4
1
5
6
7
8
9
10
3
E
E
R
Y
+
L
P1
P2
P3
Capacitors shown are 15-33 µfd,
25V Non-Polarized (NP-25V)
LE-A3
LE-A3
1
2
C
4
1
2
3
5
1
2
3
6
7
8
9
10
3
E
E
E
R
Y
+
L
K10
White
Red
Black
– 11 –
LE-A or
LE-A or
LE-AN
LE-A or
LE-AN
LE-AN
1
1
1
E
E
E
Remove the shorting link between
"E" and "-" terminals at all the LEF
master and door/sub stations.
PS12
: PS-1225UL, PS-1225S,
PS-1215DIN
LE-A3
LE-A3
1
2
3
1
2
3
E
E
To Bell
Yellow (2)
RY-AC/A
& Power
Remove the shorting link between
"E" and "-" terminals at all the LEF
master and door/sub stations.
: PS-1225UL, PS-1225S,
PS12
PS-1215DIN
PT
: Transformer for Strike
LE-A or
LE-AN
1
E
LE-A3
LE-A3
1
2
3
1
2
3
E
E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lef-3Lef-5Lef-10Lef-10s

Table of Contents