PRECAUTIONS
WARNING
(Negligence could result in death or serious injury.)
Do not dismantle or alter the unit. Fire or electric shock could result.
Do not connect any non-specified power source to the +, - terminals, and do not install two power supplies in parallel to a single input.
Fire, damage to the unit, or system malfunction could result.
Keep the unit away from water or any other liquid. Fire or electric shock could result.
When existing doorbell wires are used, it is possible that they contain AC voltage. Electric shock or unit damage could result. Make
sure doorbell transformer is disconnected before re-using those wires. Only a qualified Technician should do the installation.
Do not use DC power supply with a voltage other than what is specified. Fire or electric shock could result.
CAUTION
(Negligence could result in injury or damage to property.)
Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.
Do not install the unit in a location subject to constant vibration or impact. If dropped, injury or unit damage could result.
When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
For DC powered systems, use Aiphone power supply model specified with system. If non-specified product is used, fire, malfunction, or
unsatisfactory system performance could result.
During an electrical storm, unplug the power supply from the AC outlet. If not, power surge damage to the equipment could result.
Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
* Places under direct sunlight, or near heating equipment that varies in temperature.
* Places subject to dust, oil, or chemicals.
* Places subject to moisture and humidity extremes, such as a bathroom, cellar, greenhouse, etc.
* Places where the temperature is quite low, such as inside a refrigerated area or in front of air conditioner.
* Places subject to steam or smoke, such as near heating or cooking surfaces.
* Where interference generating devices such as dimmer switches, alarm panels, or fluorescent light fixtures are closeby.
GENERAL PRECAUTIONS
Keep the intercom wires more than 20 inches (50cm) away from AC 100~240V wiring. AC induced noise and/or unit malfunction could
result.
In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
The unit will be inoperative during a power outage.
The unit is for inside use only. Do not install outdoors.
1
SYSTEM OUTLINE & COMPONENTS
System outline
The LEF is a flexible Open Voice Selective Call Intercom system which integrates any combination of master and
sub stations. The system features selective calling from any master with handsfree reply, call-in and LED from a
variety of sub stations, selective door release, and a variety of other optional features.
BG-10C
LE-DA
PS12
LE-D
2
3
3
PT
EL-9S
OPEN VOICE SELECTIVE CALL INTERCOM
LEF-3
(3-call master)
LEF-5
(5-call master)
LEF-10
(10-call master)
LEF-10S
(10-call master w/all call)
INSTALLATION & OPERATION MANUAL
LEF-10S
20
( * )
( * )
( * )
17
12
LEF-10
LEF-5
834920 0505 N
LEF Series
15~33mfd,
8ohm horn
NP
LT-1
3
5
9
LE-A
LE-A3
LEF-3
LE-AN
LE-AN3
– 1 –
* LEF-5W, LEF-10W & LEF-10SW:
w/Terminal Box prewired
Package contents
LEF intercom
(LEF-3, 5,10 or 10S)
Packet of screws
Installation & Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Aiphone LEF Series

  • Page 1 When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result. • For DC powered systems, use Aiphone power supply model specified with system. If non-specified product is used, fire, malfunction, or •...
  • Page 2: Components Available

    Components available • Intercoms: Masters or subs, intermixable Master stations Sub stations PS-1225UL PS-1225S LEF-3 LEF-5 LEF-10 LEF-10S LE-D LE-DA LE-A LE-A3, 12V DC, 2.5A power supply LE-AN LE-AN3 3-call 5-call 10-call 10-call Surface mt. Flush mt. PS-1215DIN , 12V DC, 1.5A 1-call(w/Priv.) 3-call(w/Priv.) w/all call btn.
  • Page 3 Features • Four LEF master stations, intermixable. Models Capacity Door strike All Call transmit Video door Speaker LEF-3 4 stations CALL LEF-5 6 stations LEF-10 11 stations LE-D LEF-10S 11 stations Speaker Speaker • Optional features: CALL CALL * PanTilt Video door stations (w/ MYW-P1L, MYW-P3L, or MYW-P10L adaptor) * All Call, chime &...
  • Page 4 Do not access the PC board or components unless properly qualified. ★ Any other manufacturer’s products installed with this system (power supply, external signaling device, etc.) are not covered under Aiphone’s warranty. ★ Do not mount LEF equipment in the following places, as it may cause the system to malfunction: •...
  • Page 5: Terminal Definitions

    Occupied mode control during All Call (becomes +9V DC during All Call) Door strike activation (becomes +12V DC when “key” button is pressed) +, –: 12V DC power supply connection. Use Aiphone PS-1225UL(S). All Call control (becomes +10V DC when All Call button is pressed and activates pretone)
  • Page 6: Cable Requirements

    LEF All-Master configuration LEF all-master systems are designed to be wired in a looped fashion from the first to last master. The number of conductors for a system (not including “K” for terminals) are: Model Cable Wire number LEF-3 9 conductors #822210 (22AWG, 10 cond.) LEF-5 12 conductors...
  • Page 7 Doorbell The shorting link between “E” and “- ” IMPORTANT: Aiphone recommends using 3 conductor wiring to sub and door stations, terminals should be removed on all units even in a single master, homerun wired system. This enables a single master system where there are 3 conductors available to be expanded with more masters in the future.
  • Page 8 Six LEF-5's LEF-5 #1 LEF-5 #2 LEF-5 #3 LEF-5 #4 LEF-5 #5 LEF-5 #6 Note: This is an all master system. When one master calls another master, the person at the called master responds hands free. There is no station LED indicating which master station has called.
  • Page 9 Two LEF-5, Three LE-D w/Camera Call-up and Door Release LEF-5 #1 LEF-5 #2 LE-D or LE-DA LE-D or LE-DA LE-D or LE-DA Note: This system configuration has the master stations assigned to channels 1 and 2, and the door stations as 3 ~ 5. The relays provide a maintained contact for camera call-up, and a momentary contact for selective door release.
  • Page 10 9 LEF-10S with BG-10C and 1 Door Station LEF-10S #1 LEF-10S#2 LEF-10S#3 LEF-10S#4 LEF-10S #5 LEF-10S #6 LEF-10S #7 LEF-10S #8 LEF-10S #9 BG-10C LE-D or LE-DA – – – – – – – – – – – Remove the shorting link between PS12 DC IN “E”...
  • Page 11 3 LEF-10S, 5 Indoor Subs, 2 Door Stations with BG-10C for Chime & All Call LEF-10S #1 LEF-10S #2 LEF-10S #3 BG-10C LE-A or LE-A or LE-AN LE-A or LE-AN LE-A or LE-AN LE-D or LE-A or LE-AN LE-D or LE-DA LE-AN LE-DA...
  • Page 12: Wall Mounting

    MOUNTING • LEF-3 • LEF-5, 10, 10S • LE room subs SINGLE-GANG SINGLE-GANG ★ ★ Unplug Unplug SINGLE-GANG BOX while installing while installing ★ Prongs(4) LEF-5/10/10S 83.5mm, 83.5mm, intercom 3-5/16" 3-5/16" 83.5mm, LEF-3 3-5/16" intercom 2 screws Loosen supplied 2 screws Mounting bracket Chassis...
  • Page 13 OPERATIONS on LEF ★ LEF is a single talkpath system. While the Occupied LED is lit, do not attempt to select a station or initiate an All Call. ★ If called by a master and sub at the same time, reply to the master’s call handsfree first. When the Occupied LED goes off, select the sub station that called.
  • Page 14 Fill in CALL directory OFF OCCUPIED PRIV. TALK Station- (standby) selector Station- CALL (5 or 10) VOICE VOL. AIPHONE VOL. PRIV. TALK selector (3) OCCUPIED ALL CALL LOCK AIPHONE LEF-10S LEF-3 Voice vol. OFF (standby) Mic. cut Voice vol. In-use Door strike Mic.
  • Page 15 Problem Solution 5. LED lights don’t light up when Station LEDs only light when a sub station calls. A responding master calling master-to-master. answers handsfree, and therefore does not have to select a station number. 6. Occupied light is always on. Make sure all masters are in the OFF (standby) position.