6-4. Model: AOYG18KATA
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Indoor unit is higher than
outdoor unit *
Indoor unit is lower than
outdoor unit *
HEATING
Indoor unit is higher than
outdoor unit *
Indoor unit is lower than
outdoor unit *
6-4. Model: AOYG18KATA
15
10
1
7.5
5
0.992
0
1.000
-5
1.000
-7.5
2
-10
-15
15
10
1
7.5
5
1.000
0
1.000
-5
0.995
-7.5
2
-10
-15
- 65 -
Pipe length (m)
5
7.5
10
—
—
—
—
—
0.983
—
0.988
0.987
0.992
0.991
1.000
0.999
1.000
0.999
—
1.000
0.999
—
—
0.999
—
—
—
Pipe length (m)
5
7.5
10
—
—
—
—
—
0.982
—
1.000
0.982
1.000
0.982
1.000
0.982
0.995
0.977
—
0.993
0.975
—
—
0.972
—
—
—
6. Capacity compensation rate for pipe length and height difference
15
20
0.953
0.950
0.968
0.966
0.972
0.970
0.976
0.974
0.984
0.982
0.984
0.982
0.984
0.982
0.984
0.982
0.984
0.982
15
20
0.920
0.894
0.920
0.894
0.920
0.894
0.920
0.894
0.920
0.894
0.916
0.889
0.913
0.887
0.911
0.885
0.902
0.876