Sylvania Emerson DVC860E Service Manual page 43

Dvd player & video cassette recorder
Hide thumbs Also See for Emerson DVC860E:
Table of Contents

Advertisement

Main CBA Top View
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
F
REPLACE ONLY WITH THE SAME TYPE FUSE.
ATTENTION : POUR UNE PROTECTION CONTINUE LES RISQES
A
V
D'INCELE N'UTILISER QUE DES FUSIBLE DE MÊME TYPE.
RISK OF FIRE-REPLACE FUSE AS MARKED.
"This symbol means fast operating fuse."
"Ce symbole reprèsente un fusible à fusion rapide."
Sensor CBA Top View
BHF300F01011A
BHF300F01011B
TO SENSOR CBA
(END-SENSOR)
WF2
TP302
RF-SW
WF3
TP301
C-PB
TP513
CTL
VR501
SW-P
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
1-10-19
WF1
TP751
TO SENSOR CBA
V-OUT
(START-SENSOR)
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
DVD Open/Close
CBA Top View
1-10-20
BH9600F01011C
TP502
S-INH
BH9600F01011A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emerson dvc840eEmerson dvc845eEmerson ewd2204

Table of Contents